Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Pressure sensor for commercial air conditioning

Delivery in 3 to 5 weeks

Guilcor offers you its pressure sensor for commercial air conditioning, it allows you to measure the pressure of the refrigerant in the air conditioning system. High precision probe - Reliability - Long life.


Product features Pressure sensor for commercial air conditioning

Technical drawing Commercial air conditioning pressure sensor
Working pressure

0 ~ 4.6MPa (adjustable range)

Precision

± 1,5% FS (linear, hysteresis, repeatability)

Full error band

± 3,0% of full scale (-30 ° C to + 100 ° C) - Another high precision version is available

Operating temperature

-30°C ~ +100°C

Storage temperature

-40°C~+150°C

Protection pressure

6.9Mpa

Burst pressure

9.2Mpa

Measuring fluid

R22, R407C, R134A and other refrigerants

Durée de vie

5 million complete cycles

Vibration

11g (20~2000Hz)

Electrical interface

YAZAKI RK03FB

Protection level

IP65

Housing material

copper C3602

Pressure connection

7/16-20UNF-2B

Supply voltage

5.0±0.25VDC

Output Voltage

0.5 ~ 4.5VDC (adjustable in the range of 5V)

Supply current

10mA (max)

Load impedance

10KΩ

Output response time

3mS

Protection contre les surtensions

16VDC

Reverse voltage

-14VDC

Protection against short circuits

Yes

EMC (1 MHz - 512 MHz)

3V/m

ESD

Air 15KV contact 8KV terminal 2KV

These products can interest you

Delivery in 3 to 5 weeks
Hydraulic pressure sensor for brake

Hydraulic pressure sensor for brake

Sensor allowing the implementation of monitoring of the oil pressure of the braking system and the alarm signals...
Delivery in 3 to 5 weeks
Engine oil pressure sensor

Engine oil pressure sensor

Measure the engine oil pressure, transmitted to the ECU and then to the oil pressure gauge screen; when the pressure...