Fast response thermocouple with connection head - ATEX intrinsically safe

Reference GXI-TTIR / GXI-APTTIR

  • Design temperature range: -40 .. + 1200 ° C
  • Technological process installations in all industries
  • Installation in hazardous areas:
    Gases, vapors, mists (G): Zone 0, 1, 2
    Dust (D): Zone 20, 21, 22
    Mining: M1

Product features Fast response thermocouple with connection head - ATEX intrinsically safe

Features

  • Single and double TC
  • Mineral insulated measuring insert
  • Sheath diameter: Ø3, Ø4,5, Ø6, Ø8 mm
  • Sheath material: Inconel 600 (2.4816) or other
  • ATEX cable gland I M1, II GD, IP65 (cable diameter Ø5..10mm)
  • Output signal: TC or 4..20 mA (option)


Description

The sensor consists of an interchangeable measuring insert and an aluminum connection head where the mounting of a temperature transmitter with a 4-20 mA / HART® or Profibus®PA output signal is possible.

Insertion length, sheath diameter, connection head as well as type and number of sensors and accuracy can be individually selected for the respective application.

Temperature transmitter (option)

The transmitter is mounted inside the sensor connection head: directly on the measuring insert or in the cap 
top of the head.

The second method is advantageous because it allows to quickly change the standard measurement support without having to disassemble the transmitter; this means reduced sensor maintenance time and costs and the protection of wires from possible damage. Mounting of two transmitters inside the connection head available on request.

Type G1 Aluminum, Exe M20x1,5 cable gland, IP68
Type G2 Aluminum, Exe M20x1,5 cable gland, IP68
Type G5 Aluminum, 2 x Exe M20x1,5 cable gland, IP68
Type G6 Aluminum, 2 x Exe M20x1,5 cable gland, IP68