Product features TEMPERATURE, RELATIVE HUMIDITY, PRESSURE AND PARTICLE SENSORS - CAN KSTHPV 104 PROTOCOL
Temperature, Relative Humidity, Atmospheric Pressure and VOC Sensor - The KSTHPV 104 is designed to measure carbon dioxide concentrations, air temperature, relative air humidity, atmospheric pressure and the concentrations of volatile organic compounds. In the segment of railway vehicle applications, it is used to measure all variables in passenger compartments of train units and wagons and is part of the control system for temperature, relative humidity, atmospheric pressure and air quality.
The KSTHPV 104 temperature, relative humidity, atmospheric pressure and VOC sensor consists of a plastic ribbed head containing a printed circuit board with the individual sensors and a converter to establish communication via the CAN bus. Temperature, relative humidity, atmospheric pressure and VOCs are measured by a common internal sensing element whose signal is processed in a microprocessor and is converted to a CANopen output signal with a CiA DS 301 specification output signal The KSTHPV 104 temperature, relative humidity, atmospheric pressure and VOC sensor meets the protection index IP 30 according to standard EN 60529, as amended. The pleasant design and high-quality materials ensure that the KSTHPV 104 temperature, relative humidity, atmospheric pressure and VOC sensor does not appear intrusive even in interiors with high aesthetic requirements. You can choose the color of the box white or gray. It is recommended to install the KSTHPV 104 temperature, relative humidity, atmospheric pressure and VOC sensor on an interior wall at a height of 1,5 m, in areas with moving people, not exposed to direct sunlight and not influenced by heat from walls, heat sources or lighting.
The KSTHPV 2 temperature, relative humidity, atmospheric pressure, CO104 and VOC sensor is designed to operate in a chemically non-aggressive environment; its use should be chosen according to the temperature and chemical resistance of the head and the individual sensors. Correct operation of the sensor requires the following operating conditions:
Ambient temperature around the sensor: -30 ° C to 70 ° C, for short periods -40 to 80 ° C
Ambient relative humidity: 0 to 95% (non-condensing humidity)
Atmospheric pressure: 87 to 110 kPa
TESTS, DECLARATION, CALIBRATIONS
Type tests are carried out by a notified body according to standard EN 50155, as amended, Railway applications - Electronic equipment used on rolling stock, Art. 12.2.9, 12.2.11
- Electromagnetic compatibility according to EN 50121-3-2, as amended
- Insulation test according to EN 50155, as amended
- Shock and vibration tests according to EN 61373, as amended
The product meets the parameters in accordance with EN 45545-2, as amended, Fire protection of railway vehicles - Part 2: Requirements for the fire behavior of materials and components. May be supplied with materials that meet NFPA 130 fire safety standard, as amended.