Call us : +33 2 33 61 16 70

TEMPERATURE SENSOR KTG 6 M6, OK 12

Reference GKTG6R

Sensor type KTG 6 / R KTG 6E / R

Type of sensitive element Pt, Ni, NTC, TCx

Temperature range -40 ° C to 120 ° C (measuring range can be extended - see modifications)

Protection class IP 67 according to EN 60529

Thread / OK M 6 / OK 12

Wire length 9 mm

Housing material brass

Shielded RADOX input cable 2x0,5 mm2

Wire resistance 0,142 Ω

for 1 m of cable for 2-wire connection 0,16 Ω for

1 m cable for 2-wire connection

Response time τ0,5 <4 s (in running water at 0,4 ms-1)

Insulation resistance> 200 MΩ at 500 VDC, temperature 25 ° C ± 3 ° C and humidity <80%

Average life ≈ MTTF * 8,2 x 105 h

* Under the environmental and operational conditions specified in the approved test methodology.

Tests

Shock and vibration tests

category 2 according to EN 61373

Insulation test

KTG 6 / R 2,5 kVDC for 1 minute duration according to EN 50155

KTG 6E / R 5 kVDC for the time 1 minute according to EN 50155

Fire resistance

according to EN 45545 and according to NFPA 130

Product features TEMPERATURE SENSOR KTG 6 M6, OK 12

The KTG 6 / R and KTG 6E / R temperature sensors are designed for measuring the temperature of solid substances. In the application segment of rail vehicles, temperature sensors are used, for example, to measure the surface temperature of the baseboards of converters and coolers of performance elements of electric locomotives (drive units) where, due to lack space, the power cable is needed to guide at right angles to the base plate and in close proximity to the live performance elements.The sensor is attached to the surface of the measured parts with the M6 ​​thread, which is part of the sensor.

The temperature range of the KTG 6 / R and KTRG 6E / R temperature sensors is -40 ° C to 120 ° C, and these limits should not be exceeded even for a short time. The sensors can be used for all control systems compatible with the types of detection elements listed in the table of technical parameters. The sensor meets the protection index IP 67 according to standard EN 60529, as amended.

Temperature sensors are intended to operate in a chemically non-aggressive environment.

TESTS, DECLARATION, CALIBRATIONS

Type tests are carried out by a notified body according to standard EN 50155, as amended, Railway applications - Electronic equipment used on rolling stock, Art. 12.2.9, 12.2.11

- Insulation test according to EN 50155, as amended

- Shock and vibration tests according to EN 61373, as amended

The product meets the parameters in accordance with EN 45545-2, as amended, Fire protection of railway vehicles - Part 2: Requirements for the fire behavior of materials and components. The materials also meet the requirements of the NFPA 130 fire safety standard, as amended.

- possibility of changing thread

- Class-leading precision (except for Ni 10000/5000, Ni 10000/6180, T1 = Ni 2226, NTC 20 kΩ)

If the shielded silicone cable is changed (not in accordance with standard EN 45545-2):

- temperature range -50 ° C to 200 ° C