Product features Compressed air temperature and humidity regulator
TECHNICAL DATA
Humidity, thermostat with two relay outputs.
T + RH probe in hard anodized duralumin for compressed air up to 25 bars with 1 m of cable.
2m or 4m cable lengths available optional.
Use Case exterior and interior.
Humidity, temperature probe on a cable.
The measured values are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
INCLUDED IN DELIVERY
- H3021P
- Manual
- Traceable calibration certificate
- Free Tsensor configuration software
MEASURED VALUES
- Temperature
- Relative humidity
Maximum switching voltage, current, power of the relay output: 50V, 2A, 60VA
Audible alarm: from integrated acoustic signal - switchable
Relative humidity range: 0 to 100%
Accuracy of the relative humidity measurement: ± 2,5% relative humidity from 5 to 95% at 23 ° C
Accuracy of temperature output: ± 0,4 ° C from -30 to + 100 ° C
± 0,4% from reading at + 100 ° C
Available temperature units: degrees Celsius, Fahrenheit
Dew point temperature range: -60 to + 80 ° C
Accuracy of dew point temperature output (for details, see instruction manual): ± 1,5 ° C for the dew point + 10 ° C and more at room temperature + 25 ° C
Dew point temperature output accuracy: ± 2,0 ° C for dew point temperature 0 ° C at room temperature + 25 ° C
Dew point temperature output accuracy: ± 3,0 ° C for dew point temperature -10 ° C at room temperature + 25 ° C
Dew point temperature output accuracy: ± 6,0 ° C for dew point temperature -20 ° C at room temperature + 25 ° C
Accuracy and absolute humidity output range: ± 1,5 g / m3 at ambient temperature T <25 ° C
range 0 to 400 g / m3
Accuracy and specific humidity flow range: ± 2g / kg at ambient temperature T <35 ° C
range 0 to 550 g / kg
Accuracy and output range of mixing ratio: ± 2g / kg at ambient temperature T <35 ° C
range 0 to 995 g / kg
Accuracy and specific enthalpy output range: ± 3kJ / kg at ambient temperature T <25 ° C
range 0 to 995 kJ / kg
Temperature range : -30 to +80 ° C
LCD display operating temperature range: readable at operating temperature + 70 ° C, it is recommended to turn off the LCD screen above + 70 ° C
Temperature compensation of humidity sensor: the whole temperature range
Filtering capacity of the sensor cover: 0,025 mm - filter with stainless steel mesh
IP protection: Electronics IP65, sensors IP40
Power : 9-30Vdc, power consumption about 1W
Mechanical connection of the probe: G1 / 2 with O-ring
Probe cable length: 1m, 2m or 4m optional
Dimensions: 136 x 159 x 45 mm (W x H x D), probe length 150 mm, probe diameter 18 mm
Weight: approximately 450g
Warranty: 3 years