CONVERTER KSTUD -0 TO 10V

Reference GKSTUDR

Delivery in 3 to 5 weeks

Converter type KSTID Pt 100 KSTID Pt 1000

Input signal Pt 100/3850 Pt 1000/3850

0 to 10 V output signal

Standard measuring range

-30 ° C to 60 ° C

0 ° C to 100 ° C

0 ° C to 150 ° C

0 ° C to 200 ° C

other customer according to

Power supply 15 to 30 VDC

Nominal supply voltage Un 24 VDC

Measuring error <0,6% of the measuring range, minimum 0,5 ° C

Ambient temperature -40 ° C to 80 ° C

LEXAN box material (conforms to EN 45545)

Protection box / terminal block IP 20 / IP 00 according to EN 60529

Output voltage for breakage of the sensitive element> 14 V

Output voltage for short sensing element ~ 0 V

MTTF average life * 1,95 x 106 h, based on a theoretical calculation

*) Under the environmental and operational conditions specified in the approved test methodology

Tests

Shock and vibration tests category 1, class B according to EN 61373

Electromagnetic compatibility according to EN 50121-3-2

Insulation test 1,5 kVDC for 1 minute according to EN 50155

Fire resistance

according to EN 45545 (possible according to NFPA 130)

Product features CONVERTER KSTUD -0 TO 10V

KSTUD type converters are intended to convert the signal from resistance type temperature sensing elements Pt 100/3850 or Pt 1000/3850 into a unified 0 to 10 V signal. These converters can be used in any compatible control system. with 0 Voltage output –10 V. The standard measuring ranges of the converter are listed in the specification table. The operating temperature range is -40 to 80 ° C. These limits should not be exceeded even for a short time.

The sensors are designed to operate in a chemically non-aggressive environment.

TESTS, DECLARATION, CALIBRATIONS

Type tests are carried out by a notified body according to standard EN 50155, as amended, Railway applications - Electronic equipment used on rolling stock, Art. 12.2.9, 12.2.11

- Electromagnetic compatibility according to EN 50121-3-2, as amended

- Insulation test according to EN 50155, as amended

- Shock and vibration tests according to EN 61373, as amended

The material of the plastic box and the PCB meets a set of requirements for R 24 materials according to Table 5 for the fire risk level HL1-HL2-HL3 of the standard EN 45545-2, as amended. . May be supplied with materials that meet NFPA 130 fire safety standard, as amended.



These products can interest you

Delivery in 3 to 5 weeks
KST RS 485 temperature converters

KST RS 485 temperature converters

Converter type KST 485 Input signal Pt 1000/3850 Output signal RS 485 / MODBUS RTU Communication properties ...
Delivery in 3 to 5 weeks
CAN KST Temperature Converters

CAN KST Temperature Converters

KST converter type CAN Input signal Pt 1000/3850 CAN / CANopen output signal - CiA DS 301 Measuring range ...
Delivery in 3 to 5 weeks
KSTID CONVERTER - 4 to 20 mA

KSTID CONVERTER - 4 to 20 mA

Converter type KSTID Pt 100 KSTID Pt 1000 Input signal Pt 100/3850 Pt 1000/3850 Output signal 4 to 20 mA ...