Call us : +33 2 33 61 16 70

DIRECT CURRENT AND VOLTAGE INSULATED CONVERTER FOR PXN / R RAILWAY APPLICATIONS

Reference GPXN/RR

PXN / R type converter

Operating temperature range -25 ° C to 70 ° C

Storage temperature range -40 ° C to 80 ° C

Auxiliary power supply

16 to 300 VDC 90 to 250 VAC

on request: 20 - 60 VAC

Uninterruptible power supply: class S1 art.: 5.1.1.2

Max consumption 1,5 VA

Input signal voltage: ± 10 mV to ± 1500 V

current: from ± 50 uA to ± 10 A

Output signal 0 to 20 mA, 4 to 20 mA, 0 to 10 V

0 to ± 20 mA, 0 ± 10 V

Balancing of the output loop min. 15 V (Rz - 750 ohm) at 20 mA

Max voltage output load 10 mA

Input resistance of voltage input typ. 100 kohm / V

Current input voltage drop <0,54 V

Input current limit typ. 30 mA (electronic fuse)

Max. transfer error <0,1%

Linearity error <0,1%

Temperature error <0,01% / ° C

Time constant 1 ms, up to 300 ms on request

Protection box / terminal block IP 40 / IP 20

Weight 90 g

Environmental pollution degree PD1, PD2

Max operating voltage By insulation

wiring overvoltage category

OVI

OVI

Insulation level OVIII:

the base

make 1000V RMS

make 1000V RMS

make 1000V RMS improved

make 1000V RMS

make 600V RMS

make 300V RMS

Air distance and surface

input / output + power supply

output / power

at least 8 mm

at least 6,5 mm

Test voltage Ua input / output 5 kV RMS

Rated impulse voltage Uni: 8 kV

Tests

Elektronic equipment used on rolling stock according to EN 50155

Shock and vibration tests according to EN 61373

Electromagnetic compatibility according to EN 50121-3-2

Insulation test according to EN 50124-1

Fire resistance

according to EN 45545-2 + A1

Product features DIRECT CURRENT AND VOLTAGE INSULATED CONVERTER FOR PXN / R RAILWAY APPLICATIONS

The PXN / R module is designed for measuring direct current or voltage signals of rail vehicles. It converts the input signal to an isolated unified output signal 4..20mA, 0..20mA, 0..10V, 0 .. ± 10V or 0..20mA. It can process DC signals in the voltage range of ± 10mV to ± 1500V and the current range of ± 50uA to ± 10A. The module is typically used to measure signals from medium voltage shunts and dividers. The output of the converter is an active signal isolated from the input and the auxiliary supply.

PXN / R output loop powered.

measures and isolates an input direct current or voltage signal

 it activates the bipolar input and output signal

rated impulse voltage Uni: 8 kV

air distance and inlet / outlet surface: min. 8 mm

test voltage Ua input / output: 5 kV RMS

auxiliary power supply 16-300 VDC 90-250 VAC

DIN 35 rail installation

conversion accuracy <0,1%

time constant 1ms, up to 300ms on request

TESTS, DECLARATIONS, CALIBRATIONS

Electronic equipment used on rolling stock in accordance with EN 50155, as amended

Electromagnetic compatibility according to standard EN 50121-3-2, as amended

Insulation coordination according to standard EN 50124-1, as amended

Shock and vibration tests according to standard EN 61373, as amended

Fire protection according to standard EN 45545-2 + A1, as amended, meets all the requirements for monitored products according to table 2 - the printed circuit meets all of the R24 requirements - the housing meets all R26 requirements

These products can interest you