Accuracy class of Pt100 probes

list Category: Temperature sensors

Pt100 sensors are the most common type of platinum resistance thermometer. Resistance thermometers are mostly Pt100.

Precision RTD Pt, Ni, Cu - Class A, Class B, 1/3 DIN, 1/10 DIN

 

CLASS B

CLASS A

CLASS 3 - 1/3 B (1/3 DIN)

CLASS 5 - 1/10 B (1/10 DIN)

-200 ° C
1.30 ° C
0.55 ° C
0.39 ° C
0.38 ° C
-150 ° C
1.05 ° C
0.45 ° C
0.23 ° C
0.21 ° C
-100 ° C
0.80 ° C
0.35 ° C
0.15 ° C
0.12 ° C
-90 ° C
0.75 ° C
0.33 ° C
0.14 ° C
0.10 ° C
-80 ° C
0.70 ° C
0.31 ° C
0.13 ° C
0.09 ° C
-70 ° C
0.65 ° C
0.29 ° C
0.12 ° C
0.08 ° C
-60 ° C
0.60 ° C
0.27 ° C
0.11 ° C
0.07 ° C
-50 ° C
0.55 ° C
0.25 ° C
0.10 ° C
0.06 ° C
-40 ° C
0.50 ° C
0.23 ° C
0.10 ° C
0.06 ° C
-30 ° C
0.45 ° C
0.21 ° C
0.09 ° C
0.05 ° C
-20 ° C
0.40 ° C
0.19 ° C
0.09 ° C
0.04 ° C
-10 ° C
0.37 ° C
0.17 ° C
0.08 ° C
0.03 ° C
0 ° C
0.30 ° C
0.15 ° C
0.08 ° C
0.03 ° C
10 ° C
0.35 ° C
0.17 ° C
0.09 ° C
0.04 ° C
20 ° C
0.40 ° C
0.19 ° C
0.10 ° C
0.04 ° C
30 ° C
0.45 ° C
0.21 ° C
0.11 ° C
0.05 ° C
40 ° C
0.50 ° C
0.23 ° C
0.12 ° C
0.06 ° C
50 ° C
0.55 ° C
0.25 ° C
0.13 ° C
0.07 ° C
60 ° C
0.60 ° C
0.27 ° C
0.14 ° C
0.08 ° C
70 ° C
0.65 ° C
0.29 ° C
0.16 ° C
0.09 ° C
80 ° C
0.70 ° C
0.31 ° C
0.17 ° C
0.10 ° C
90 ° C
0.75 ° C
0.33 ° C
0.18 ° C
0.11 ° C
100 ° C
0.80 ° C
0.35 ° C
0.19 ° C
0.12 ° C
110 ° C
0.85 ° C
0.37 ° C
0.20 ° C
0.13 ° C
120 ° C
0.90 ° C
0.39 ° C
0.21 ° C
0.14 ° C
130 ° C
0.95 ° C
0.41 ° C
0.22 ° C
0.15 ° C
140 ° C
1.00 ° C
0.43 ° C
0.24 ° C
0.15 ° C
150 ° C
1.05 ° C
0.45 ° C
0.25 ° C
0.16 ° C
160 ° C
1.10 ° C
0.47 ° C
0.26 ° C
0.17 ° C
170 ° C
1.15 ° C
0.49 ° C
0.27 ° C
0.18 ° C
180 ° C
1.20 ° C
0.51 ° C
0.29 ° C
0.19 ° C
190 ° C
1.25 ° C
0.53 ° C
0.30 ° C
0.21 ° C
200 ° C
1.30 ° C
0.55 ° C
0.31 ° C
0.22 ° C