The sensing element.
RTD, NTC, PTC, thermocouple or digital technology. Match temperature range, accuracy and the receiving input.
Compare sensing technologies ↗GUILCOR / TEMPERATURE PROBES
The measurement starts with a sensor.
The right probe puts it in the right place.
Compare 11 probe families by measuring point, mounting and construction. Start with your application, then build the specification around it.
THE MEASURING POINT. THE MOUNTING. THE COMPLETE ASSEMBLY.
01 / START WITH THE WHOLE ASSEMBLY
These are connected decisions. A probe family describes how the assembly meets your equipment; it does not, by itself, define the sensing element or its performance.
RTD, NTC, PTC, thermocouple or digital technology. Match temperature range, accuracy and the receiving input.
Compare sensing technologies ↗Put the sensing point where it needs to be. Define the shape, dimensions, mounting and contact with the medium.
Explore probe families ↗Specify the cable, connector or head, alongside sealing, materials and the conditions each component sees.
Prepare the requirements ↗One assembly can combine several features: a threaded mounting, a sealed construction and a connection head, for example.
02 / A CLEAR STARTING POINT
Three short steps to narrow the mechanical format. This guide gives you a starting family and questions to resolve with our team.
03 / THE FORM FACTOR LIBRARY
Start with what makes each family different. Open a family to explore its construction, application examples and specification guide.

Plain tube / insertion
A clean, straight fit.
A prepared opening, pocket or mounting arrangement already defines where the probe sits.

Fixed process connection
Match the process port.
The equipment has a threaded port and needs a defined insertion point.

Spring-loaded mounting
Locate. Turn. Seat.
A mating bayonet adapter and spring arrangement locate the sensing tip in tooling or machinery.

External surface measurement
Measure from the outside.
The available measuring point is a pipe wall, plate or machine surface.

Insertion into a sample
Reach the sample’s core.
A probe must be inserted into food, material or another sample for a core-temperature check.

Surrounding air
Read the air around you.
The measurement target is air in a room, technical space or outdoor location.

Stator slot integration
Fit the available slot.
A motor or generator has a defined stator slot or flat channel for thermal monitoring.

Embedded thermal monitoring
Plan it into the winding.
The sensing point is integrated within or around a motor, transformer or other winding.

Moisture / sealing
Define every wet point.
The tip, cable transition or connection is exposed to moisture, washing or immersion.

Sheathed construction
Follow the installation.
A sheathed assembly must follow a specified route or reach a constrained measuring point.

Accessible field wiring
Bring the connection close.
The installation needs an accessible local enclosure for terminals or a separately specified transmitter.
GOING BEYOND THE PROBE?
Custom PCBA design is a separate engineering service. Explore it when your project needs a dedicated electronic assembly.
04 / SEE THE DIFFERENCES
Compare the mechanical choices before getting into reference-specific dimensions or ratings. Several of these requirements may belong in one assembly.
| Probe family | Main role | What makes it different | Define first |
|---|---|---|---|
| Smooth tube ↗ | Plain tube / insertion | Plain tube geometry; the fixing and sealing arrangements are specified separately. | Tube diameter, insertion length and retention. |
| Threaded ↗ | Fixed process connection | Adds a threaded interface. A matching thread alone does not establish a pressure-tight assembly. | Full thread designation, sealing seat, insertion depth and process pressure. |
| Bayonet ↗ | Spring-loaded mounting | Uses a matching cap and adapter, often with a spring to maintain the intended tip contact. | Adapter geometry, working depth and spring position. |
| Surface contact ↗ | External surface measurement | Measures at the contact surface. That is not automatically the temperature of the fluid or winding inside. | Surface shape, contact area, attachment and the temperature you need to know. |
| Stick-in ↗ | Insertion into a sample | Designed around insertion into a sample, rather than a fixed, sealed process connection. | Sample material, insertion depth, handling and cleaning. |
| Ambient ↗ | Surrounding air | Location and air circulation matter. A nearby equipment surface is a different measuring point. | Airflow, sunlight, nearby heat sources and the controller input. |
| Slot ↗ | Stator slot integration | The finished insulated probe must fit the slot envelope and assembly sequence. | Usable width, thickness, length, insulation and lead exit. |
| Winding ↗ | Embedded thermal monitoring | Integration follows the winding design. It does not necessarily use a dedicated stator slot. | Sensing position, insulation, impregnation or curing, and signal requirements. |
| Waterproof ↗ | Moisture / sealing | Describes sealing needs, not a single mounting method. Confirm the rating and conditions of the complete assembly. | Liquid, wet areas, cleaning, immersion depth and duration. |
| Jacketed ↗ | Sheathed construction | Sheath construction and forming are specified for the selected reference. Flexibility does not imply repeated-flex duty. | Sheath construction, protected sensing zone and permitted bend limits. |
| Connection head ↗ | Accessible field wiring | Defines the wiring enclosure. A head does not automatically include a transmitter or thermowell. | Signal path, cable entry, head ambient conditions and service clearance. |
The sensing tip, transition, cable, connector and head can have different limits.
Drawings, access, pressure, vibration and cleaning conditions complete the picture.
Confirm the sensing characteristic, output, wiring and controller input together.
05 / BEFORE YOU SPECIFY
A little clarity at the start helps define the right assembly.
The sensing element converts temperature into an electrical response. The probe is the assembly that places and protects it in the application, including its tube or housing, mounting, cable and connection. Choose the measurement technology and the mechanical construction together.
Yes, these describe different requirements. Threaded describes a mounting interface; waterproof describes protection from specified water exposure. Confirm the complete assembly, including the tip, cable transition, connection, process seal and agreed test conditions.
No. A family name does not establish the sensing element, output, accuracy or temperature range. Match the sensor and wiring to your controller, then confirm that the complete probe construction is suitable.
A surface probe measures the temperature at the outside contact point. The relationship to fluid temperature depends on the pipe, contact, insulation, flow and surrounding conditions. Review that difference against the measurement you need.
No. A thermowell or protection tube and the measuring insert are separate parts of an installation. Send the internal dimensions, required insertion depth and process conditions so the mechanical fit and response can be reviewed.
Start with the application and measured medium, temperature range, mounting drawing, dimensions, sensing element or controller input, cable or connector, and quantity. Add moisture, pressure, cleaning and certification requirements where relevant. Unknown details can be discussed with the GUILCOR team.
FROM A MEASURING POINT TO A COMPLETE PROBE
A photo, a drawing or a description is enough to start the conversation.