Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Temperature probe with steel connection head and plunger

Reference GNS180R

Delivery in 3 to 5 weeks
  • Resistance temperature sensors.
  • Contact measurement of liquid and gaseous substances.
  • Standard temperature range of -30 to +150°C.
  • Operates in a chemically non-aggressive environment.
972.11KB Download

GNS180R Datasheet | Temperature probe with steel connection head and contact tip

Product features Temperature probe with steel connection head and plunger

DESCRIPTION AND APPLICATION

These resistance-type sensors are intended for measure by contact the temperatures of liquid and gaseous substances. These sensors are manufactured in two versions: the small connection head with resistance output and the large connection head with 4 to 20 mA output.

The sensors are designed to be mainly used in the food industry. The sensor - central support combination is suitable for temperature measurement in air conditioning ducts. The sensor/thermowell combination is suitable for measuring the temperature in pipes.

The sensor variant with welded thread is ideal for direct measurement of fluids in ducts. The standard operating temperature range for active sensors is between -30 and +150°C; for passive sensors, it is between -30 and +200°C.

The sensors are designed to operate in a chemically non-aggressive environment.

ACCESSORIES

  • K120 metal central support
  • JS 130 stainless steel thermowell
  • CONEC 43-00092 input connector 
  • Connection cable with straight connector RKt or rectangular connector RKWt
  • Screw with collar or cutting rings - if different immersion lengths of the temperature sensor are set

DECLARATION, CERTIFICATION, CALIBRATION

  • The manufacturer provides an EU declaration of conformity.
  • Calibration - The final metrological control - comparison with standards or working instruments - is carried out for all products. The continuity of working standards and measuring instruments is ensured within the meaning of Article 5 of Law No. 505/1990 on metrology. We offer the possibility to supply the calibrated sensors (according to the requirements of EN ISO / IEC 17025) or in an accredited laboratory.
  • Features
  • Cable schematics
  • Dimensional draft
  • Download
Sensor type 
(K - with connector)
NS180P 
NS-180K
NS181P
NS-181K
NS182P
NS-182K
NS380P
NS-380K
NS381P
NS-381K
Sensitive element type Nor 1000/5000 Nor 1000/6180 Ni 891 Nor 10000/5000 Nor 10000/6180
Measuring range -50 to 200 ° C (ambient temperature of the connection head -30 to 100 ° C)
Maximum continuous current 1 mA 1 mA 1 mA 0.3 mA 0.3 mA

Sensor type 
(K - with connector)
NS183P
NS-183K
PTS 180P 
PTS 180K
PTS 280P 
PTS 280K
PTS 380P 
PTS 380K
HS180P 
HS 180K
Sensitive element type T1 = Ni 2226 Point 100/3850 Point 500/3850 Point 1000/3850 NTC 20Ω thermistor
Measuring range -50 to 150 ° C -50 to 200 ° C (ambient temperature of the connection head -30 to 100 ° C) -30 to 150 ° C
Maximum continuous current 0.7 mA 3 mA 1.5 mA 1 mA 10 mW *)

*) maximum power consumption

Sensor type 
(k - with connector)
PTS 580P 
PTS 580K
Footnotes
Sensitive element type Point 1000/3850
Output signal 4 to 20 mA
Measuring ranges -50 to 50 ° C 
-30 to 60 ° C 
0 to 35 ° C 
0 to 100 ° C 
0 to 150 ° C
ambient temperature around the connection head -30 to 70 ° C
Power supply (U) 11 to 30 V DC recommended value 24 V DC
Load resistance 150 Ω for 12 VDC power supply 
700 Ω for 24 VDC power supply
Output signal 
breaking the sensitive element
> 24 mA
Output signal 
- short circuit of the detection element
<3.5 mA

OTHER PARAMETERS
Precision class Elements sensitive to Ni: class B, Δt = ± (0,4 + 0,007t), for t ≥ 0; Δt = ± (0,4 + 0,028 | t |), for t ≤ 0 in ° C; 
Elements sensitive to pt: class B according to EN 60751, Δt = ± (0,3 + 0,005 | t |) in ° C 
NTC 20 kΩ: ± 1 ° C for the range from 0 to 70 ° C
Measurement error <0,6% of the measuring range, minimum 0.5 ° C
Sensor connection according to the wiring diagram
Standard length of rod L1 70, 120, 180, 240 mm
Response time τ 0,5 <9 s (in white water at 0,4 ms -1 )
Cable in 
version - version with cable
Shielded PVC 2 x 0,25 mm 2
Connector type in 
sensors head with connector
Lumberg RSFM4, M 12
Standard cable lengths 1, 2, 5, 10m
Insulation resistance > 200 MΩ at 500 V DC, 25 ° ± 3 ° C; humidity <85%
Protection sign IP 67 according to EN 60529
Sensor rod material stainless steel DIN1.4301
Connection head material DIN 1.4301 stainless steel
operating conditions ambient temperature: -30 to 100 ° C; -30 to 70 ° C with converter 
relative humidity: max. 100% (at room temperature 25 ° C) 
atmospheric pressure: 70 to 107 kPa
Weight about 0,25 kg

These products can interest you