Temperature sensor - IP68 - Metal connection head

Probe with connection head - IP68 *Step required

Delivery in 3 to 5 weeks
Description and application
These resistance sensors are designed for contact measurement of temperatures up to 400 ° C. Temperature sensors, combined with a central bracket or thermowell, can be used to measure temperature in various applications in an environment. industrial. The sensor variant with welded thread is ideal for direct measurement of fluids in ducts. The sensors meet the protection level IP 68 in accordance with standard EN 60529. The standard operating temperature range is -50 to 400 ° C. The sensors can be used for any control system compatible with the output signals of the sensing elements or the output signals shown in the table of types of detection elements. The sensors are designed to operate in a chemically non-aggressive environment.
Unit price
59,89 €
Final price
59,89 €
Your configuration:

Secure Payments

All payments are secure and approved.

Best price guarantee

Contact us to define your payment term.

+33-233-611-670

English - French - German - Spanish

International shipping

EXPRESS OR STANDARD delivery.

ACCESSORIESIP68 connection head probeIp68 head probe

  • central metal support K 120
  • JPTS 41 stainless steel thermowell
  • screw with collar or cutting rings - if different immersion lengths of the temperature sensor are set

DECLARATION, CERTIFICATION, CALIBRATION

  • The manufacturer provides an EU declaration of conformity.
  • Calibration - Final metrological control
  • Features
  • Cable schematics
  • Dimensional draft
  • Download
Sensor type with smooth rod 
Sensor type with welded screw connection
PTS 441 
PTS 461
PTS 443 
PTS 463
PTS 445 
PTS 465
Sensitive element type
100 pt 500 pt 1000 pt
Class B measuring range
-50 to 400 ° C
Maximum continuous current
3 mA 1.5 mA 1 mA

Probe with connection head - IP68

Type of smooth rod sensor 
Type of sensor with welded thread
PTS 451 
PTS 471
Notes
Sensitive element type
Pt 1000/3850
Output signal
4 to 20 mA
Measuring ranges
-50 to 50 ° C 
0 to 100 ° C 
0 to 150 ° C 
0 to 200 ° C 
0 to 400 ° C
ambient temperature around the connection head -30 to 70 ° C
Power supply (U)
11 to 30 V DC recommended value 24 V DC
Load resistance
150 Ω for 12 VDC power supply 
700 Ω for 24 VDC power supply
Output signal - detection element failure
> 25 mA
Output signal - detection element short circuit
<3.5 mA

OTHER PARAMETERS
Precision class
Class B according to EN 60751, Δt = ± (0.3 + 0.005 | t |) in ° C
Measurement error
<0,6% of the measuring range, minimum 0.5 ° C
Sensor awareness
according to the wiring diagram
Standard length of rod L1
50, 100, 160, 220, 280, 400 mm
Nominal rod pressure
PN 63 (with wire)
Response time
τ0,5 <9 s (in white water 0,4 ms -1 )
Recommended wire section
0,35 to 1,5 mm 2
Thead types for PTS 61, PTS 63, PTS 65, PTS 71 G 1/2 "; M 20 x 1,5; M 27 x 2
Isolation resistance
> 200 MOhm at 500 V DC, 25 ° C ± 3 ° C; humidity <85%
Ingress protection
IP 54 according to EN 60529
Material of the stem
DIN 1.4301 stainless steel
Connection head material
aluminum alloy LIMATHERM B
Working conditions
ambient temperature: -30 to 100 ° C; -30 to 70 ° C with converter 
relative humidity: max. 100% (at room temperature 25 ° C)
atmospheric pressure: 70 to 107 kPa

Weight

about 0,25 kg

MAXIMUM FLOW SPEED OF MEASURED MEANS - AIR AND WATER / WATER VAPOR [ms -1 ]

Length of thermowell / rod > 60 to 100 mm > 100 to 160 mm > 160 to 220 mm > 220 to 400 mm
Values ​​for the version with thread
Zones Zones Zones Zones

Note: manufacturer reserves the right to modify the design and technical characteristics of the products. For real information, please always contact your dealer.

10000 Products

Information

Measured
Temperature
Product Type
Head / terminal probes
Communication
4 ... 20mA
DS18B20 digital