Delivery in 3 to 5 weeks

Reference G04.02
Sensor type | G04.02 | |
Typical thermocouple | "J" and "K" (others on request), single and double | |
Protection sign | IP 55, 54 and 50 according to EN 60529 | |
Design | with an isolated measuring point or with a measuring point connected to the jacket | |
Case diameter |
1 mm | |
Length of measuring part L |
from 20 to 300 mm as standard, others on request | |
Measuring range - on the measuring point |
Type "K" up to 800 ° C type "J" up to 700 ° C other by type |
|
Precision class | 2 in accordance with EN 60584 and DIN 43 710, 1 other | |
Cover material / housing material |
Inconel 2.4816 for TC "K", stainless steel DIN 1.4541 for TC "J" | |
Sensor body | flexible, moldable | |
Wire protection | unshielded silicone 2 × 0,22 mm 2 up to 200 ° C IP 55 / IP 67 PTFE shielded 2 × 0,22 mm 2 up to 260 ° C (short term 300 ° C) IP 54 / IP 64 + metal braid 2 × 0,22 mm 2 up to 400 or 600 ° C IP 50 in Unshielded PVC 2 x 2,22 mm 2 up to 105 ° C, IP 55 / IP 67 |