Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Temperature and humidity sensor - Modbus RS485

Reference GSTH102R

Delivery in 3 to 5 weeks

Sensor temperature and relative humidity - STH 102 is designed to measure temperature and relative humidity in areas protected from water.

Temperature and relative humidity sensor - The STH 102 consists of a plastic head with ribs in which a printed circuit board with individual sensors and a converter are located to ensure communication via the RS 485 bus. The temperature and relative humidity are measured by a common internal sensor. microprocessor and converted into MODBUS RTU output signal. The sensors comply with protection class IP 30 according to EN 60529.

415.16KB Download

Datasheet GSTH102 | Temperature and humidity probe - Modbus RS485

Product features Temperature and humidity sensor - Modbus RS485

Room sensor

Temperature and relative humidity sensor - STH 102 is designed to operate in a chemically non-aggressive environment. The method of use must be chosen according to the temperature and the chemical resistance of the head. STH 102 temperature and relative humidity sensorThe operating conditions to ensure correct operation are as follows:

  • ambient temperature: -40 to 80 ° C
  • relative humidity: 0 to 95% (non-condensing)
  • atmospheric pressure: 87 to 106 kPa
Sensor type STH-102
Temperature measurement range -40 to 80 ° C
Temperature measurement accuracy ± 0,5 ° C in the range of 0 to 65 ° C 
± 0,7 ° C in the range of 65 to 80 ° C 
± 1,1 ° C in the range of -40 to 0 ° C
Relative humidity measurement 0 to 95%
Relative humidity measurement accuracy ± 3% in the range of 10 to 90% 
± 4,5% in the range of 0 to 10% and 90 to 95%
Output signal RS485 / MODBUS
Galvanic isolation No, can be provided on request
Supply voltage 15 to 30 V DC
Nominal supply voltage U n 24 V DC
The consumption max: 500mW 
typical: 300 mW
Degree of protection IP 30 according to EN 60529
Head dimensions 71,9 x 59 x 27 mm
Head material lexan
The weight min 35g
Recommended conductor cross-section 0,14 to 1 mm 2



Note:
The manufacturer reserves the right to modify the design and technical characteristics of the products.

SENSOR INSTALLATION AND MAINTENANCE
The sensors are designed to be mounted on a wall or other vertical surface. For fixing, it is necessary to prepare the required holes for mounting screws using a template (supplied with the sensor).
Before connecting the power cable, it is necessary to separate the perforated cover from the plastic base. Remove the cover and insert the cable through the 9 mm hole, apply the base to the surface and screw with two screws or bolts. The length of the bolts or fixing screws for fixing should be chosen according to the thickness of the plastic base. Connect the power cable to the terminals in accordance with the “Wiring” section. Diagram: place the perforated cover on the fixed base and lock it by clicking on it. After installation and connection to the electrical measuring device, the sensor is ready for use. The sensor does not require any particular maintenance.