Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Intrinsically safe ATEX humidity and temperature transmitter with 4-20mA output

Reference AR003866

Delivery in 3 to 5 weeks
  • Temperature and humidity.
  • Exterior and interior.
  • Calibration certificate.
  • ATEX certification.
2.77MB Download

Introduction Manual | Intrinsically safe ATEX humidity and temperature transmitter with 4-20mA output

797.1KB Download

Quick Start | Intrinsically safe ATEX humidity and temperature transmitter with 4-20mA output

1005.41KB Download

Guide | Intrinsically safe ATEX humidity and temperature transmitter with 4-20mA output

Product features Intrinsically safe ATEX humidity and temperature transmitter with 4-20mA output

TECHNICAL DATA

Temperature transmitter relative humidity ATEX certified.

Use Case exterior and interior.

The measured values ​​are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

ATEX certification for use in potentially explosive environments. 

INCLUDED IN DELIVERY

  • T3110Ex
  • Manuel
  • Traceable calibration certificate
  • Free Tsensor configuration software 


MEASURED VALUES

- Temperature
- Relative humidity
- Calculated values ​​(dew point, etc.)

Relative humidity range: 0 to 100%

Relative humidity measurement accuracy: ± 2,5% relative humidity 5 to 95% at 23°C

Temperature output accuracy: ± 0.4 ° C

Available temperature units: degrees Celsius, Fahrenheit

Dew point accuracy and output range - for details see graphs: ± 1,5 °C at ambient temperature T <25 °C and relative humidity > 30%
range -60 to +80°C

Dew point output accuracy and range - for details see charts Dew point accuracy and output - for details see charts : ± 1,5 g / m3 at ambient temperature T <25 °C
range 0 to 400 g/m3

Accuracy and specific humidity output range: ± 2 g / kg at ambient temperature T < 35 °C
range 0 to 550 g/kg

Mix Ratio Output Accuracy and Range: ± 2g / kg at ambient temperature T < 35 °C
range 0 to 995 g/kg

Accuracy and specific enthalpy range: ± 3 kJ / kg at ambient temperature T < 25 °C
range: 0 to 995 kJ/kg

Temperature operating range: -30 to + 60 ° C

Operating temperature range (case environment): up to +60°C

LCD screen usage temperature range: readable at an operating temperature of +70°C, it is recommended to turn off the LCD screen above 70°C

Humidity sensor temperature compensation range: 4-20mA, galvanically isolated temperature range

Current outputs - two-wire connection: 4-20mA, galvanically isolated

Configuration of outputs and output range: user adjustable from PC

Sensor Cover Filtering Capacity: 0.025mm - filter with stainless steel mesh

Protection of the housing with electronics: IP65 electronics, IP40 sensors

Supply : 9-30Vdc

Dimensions: 88,5 x 170 x 39,5 mm (L x H x D), shaft length 75 mm

Weight: about 150g

Warranty: 3 years ago, 

These products can interest you