RH + T + TDP compressed air sensor with 0-10 V output *Step required

AR005146
  • Temperature and humidity.
  • T + RH probe in duralumin.
  • compressed air up to 25 bars.
  • Exterior and interior.
Unit price
332,00 €
Final price
332,00 €
Your configuration:

Secure Payments

All payments are secure and approved.

Best price guarantee

Contact us to define your payment term.

+33-233-611-670

English - French - German - Spanish

International shipping

EXPRESS OR STANDARD delivery.

TECHNICAL DATA

Transmitter temperature and humidity.

T + RH probe hard anodized duralumin for compressed air up to 25 bar with 1 m cable.

Cable lengths of 2m or 4m are available as an option.

Use exterior and interior.

The measured values ​​are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

Power supply - also powered by 24 Vac

INCLUDED IN DELIVERY

  • AR005146
  • Manual
  • Traceable calibration certificate
  • Free Tsensor configuration software


MEASURED VALUES

- Temperature
- Relative humidity
- Calculated values ​​(dew point, etc.)

Relative humidity range: 0 to 100%

Accuracy of the relative humidity measurement: ± 2,5% relative humidity from 5 to 95% at 23 ° C

Accuracy of temperature output: ± 0,4 ° C from -30 to + 100 ° C
± 0,4% from reading at + 100 ° C

Available temperature units: degrees Celsius, Fahrenheit

Dew point temperature range: -60 to +80 ° C

Accuracy of dew point temperature output (for details, see instruction manual): ± 1,5 ° C for the dew point + 10 ° C and more at room temperature + 25 ° C

Dew point temperature output accuracy: ± 2,0 ° C for dew point temperature 0 ° C at room temperature + 25 ° C

Dew point temperature output accuracy: ± 3,0 ° C for dew point temperature -10 ° C at room temperature + 25 ° C

Dew point temperature output accuracy: ± 3,0 ° C for dew point temperature -10 ° C at room temperature + 25 ° C

Accuracy and absolute humidity output range: ± 1,5 g / m3 at ambient temperature T <25 ° C
range 0 to 400 g / m3

Accuracy and specific humidity flow range: ± 2g / kg at ambient temperature T <35 ° C
range 0 to 550 g / kg

Accuracy and output range of mixing ratio: ± 2g / kg at ambient temperature T <35 ° C
range 0 to 995 g / kg

Accuracy and specific enthalpy output range: ± 3kJ / kg at ambient temperature T <25 ° C
range 0 to 995 kJ / kg

Housing operating temperature range with electronics: -30 to + 80 ° C

LCD display operating temperature range: readable at operating temperature + 70 ° C, it is recommended to turn off the LCD screen above + 70 ° C

Humidity sensor temperature compensation range: the whole temperature range

Voltage outputs: 0-10V, outputs are not galvanically isolated - have common ground

Output configuration and output range: user adjustable from PC

Sensor filtering capacity covers: 0,025 mm - filter with stainless steel mesh

Protection of the case with electronics: Electronics IP65, sensors IP40

Power : 15-30Vdc, maximum consumption 20mA, 24Vac

Mechanical connection of the probe: G1 / 2 with O-ring

Probe cable length: 1m, 2m or 4m optional

Display unit dimensions: 88,5 x 114 x 39,5 mm (W x H x D), probe length 150 mm, probe diameter 18 mm

Weight: approximately 260g

Warranty: 3 years 

AR005146