Call us : +33 2 33 61 16 70

Industrial temperature and humidity transmitter - RS232 output

Reference AR003871

Personalization

Don't forget to save your personalization to be able to add it to the basket

250 characters max
  • Temperature and humidity.
  • Exterior and interior.
  • Probe on a cable.
  • Convertible securities.
5.29MB Download

User Manual | Industrial temperature and humidity transmitter - RS232 output

876.26KB Download

Protocol | Industrial temperature and humidity transmitter - RS232 output

2.21MB Download

Quick Start | Industrial temperature and humidity transmitter - RS232 output

Product features Industrial temperature and humidity transmitter - RS232 output

TECHNICAL DATA

Transmitter temperature and humidity.

Use Case exterior and interior.

Humidity, temperature probe on a cable.

The measured values ​​are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. 

INCLUDED IN DELIVERY

  • AR003871
  • Manual
  • Traceable calibration certificate
  • Free Tsensor configuration software

MEASURED VALUES

- Temperature
- Relative humidity
- Calculated values ​​(dew point, etc.)

Relative humidity range: 0 to 100%

Accuracy of the relative humidity measurement: ± 2,5% relative humidity from 5 to 95% at 23 ° C

Accuracy of the relative humidity measurement: ± 0,4 ° C from -30 to + 100 ° C
± 0,4% from reading at + 100 ° C

Available temperature units: degrees Celsius, Fahrenheit

Dew point output accuracy and range - for details see graphs: ± 1,5 ° C at ambient temperature T <25 ° C and relative humidity> 30%
range -60 to +80 ° C

Accuracy and absolute humidity output range: ± 1,5 g / m3 at ambient temperature T <25 ° C
range from 0 to 400 g / m3

Accuracy and specific humidity output range: ± 2 g / kg at room temperature T <35 ° C
range 0 to 550 g / kg

Accuracy and output range of mixing ratio: ± 2g / kg at ambient temperature T <35 ° C
range from 0 to 995 g / kg

Precision and range of specific enthalpies: ± 3 kJ / kg at ambient temperature T <25 ° C
range: 0 to 995 kJ / kg

Housing operating temperature range with electronics: -30 to +80 ° C

LCD display operating temperature range: readable at an operating temperature of + 70 ° C, it is recommended to turn off the LCD screen above 70 ° C

Humidity sensor temperature compensation range: the entire temperature range

Communication protocol : ModBus RTU and Advantech ADAM compatible protocol

Communication speed: 110 to 115200 Bd

Filtering capacity of the sensor cover: 0.025mm - filter with stainless steel mesh

Housing protection with electronics: Electronics IP65, sensors IP40

Supply : 9-30Vdc, current consumption about 6mA

Probe cable length: 1m, 2m or 4m optional

Display unit dimensions: 88,5 x 114 x 39,5mm (W x H x D), probe length 88mm, probe diameter 18mm

Weight: about 290g - 1m probe

Warranty: 3 years 