Description and application
These resistance sensors are intended for measuring the contact surface temperature. the available sensors, including fastening strap, are suitable for temperature measurement on the pipes.
The dimensions of the sensor allow the sensor to be placed even under the pipe insulation. The standard operating temperature range is between -50 and 130 ° C.
The sensitive element is constructed to be isolated from ambient influence. The sensors can be used for any compatible control system with the sensing element output signals or the output signals shown in the sensing element type table.
Accessories
- heat conductive paste up to 200 ° C, 5g
DECLARATION, CERTIFICATION, CALIBRATION
- The manufacturer provides an EU declaration of conformity.
- Calibration - The final metrological control - comparison with standards or working instruments - is carried out for all products. The continuity of working standards and measuring instruments is ensured within the meaning of Article 5 of Law No. 505/1990 on metrology. We offer the possibility to supply the calibrated sensors (according to the requirements of EN ISO / IEC 17025) or in an accredited laboratory.
Sensitive element type |
Nor 1000/5000 | Nor 1000/6180 | Ni 891 | Nor 10000/5000 | Nor 10000/6180 |
Measuring range |
-50 to 130 ° C | ||||
Maximum continuous current |
1 mA | 1 mA | 1 mA | 0.3 mA | 0.3 mA |
Sensitive element type |
T1 = Ni 2226 | Point 100/3850 | Point 500/3850 | Point 1000/3850 | 20 kΩ NTC thermistor |
Measuring range |
-50 to 130 ° C | ||||
Maximum continuous current |
0.7 mA | 3 mA | 1.5 mA | 1 mA | 10 mW *) |
*) maximum power consumption
OTHER PARAMETERS | |
Accuracy class **) | Elements sensitive to Ni: class B, Δt = ± (0,4 + 0,007t), for t ≥ 0; Δt = ± (0,4 + 0,028 | t |), for t ≤ 0 in ° C Sensitive elements of Pt: B according to EN 60751, Δt = ± (0,3 + 0,005 | t |) in ° C NTC 20 kΩ: ± 1 ° C for the range 0 to 70 ° C |
Sensor connection |
according to the wiring diagram |
Response time |
sensor type S150A τ 0,5 ≤ 10s, τ 0,9 ≤ 45 s (on the smooth surface without paste) |
Isolation resistance |
> 200 MΩ at 500 V DC, 25 ° ± 3 ° C; humidity <85% |
Protection sign |
IP 65 according to EN 60529 |
Protective tube material |
brass |
Input cable | shielded silicone 2 x 0,22 mm 2 shielded silicone 4 x 0,15 mm 2 |
Standard cable length |
2, 5, 10 |
Plastic protection material |
POLYAMIDE type S150A |
Standard collar length |
40 cm |
Minimum pipe diameter |
20 mm |
Working conditions |
ambient temperature: -50 to 130 ° C relative humidity: max. 100% (at room temperature 25 ° C) atmospheric pressure: 70 to 107 kPa |
Weight | about 0,15 kg |
**) Regulated by immersing the sensor in a liquid, no method error is taken into account - influence of the ambient temperature and the environment, uneven surface, etc. In terms of two connections, the impact of wire resistance be added. At a temperature of 20 ° C, the impact of lead resistance is 0,4 ° C / 1 m.