Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

TP 16 Resistive Paired Probe

Delivery in 3 to 5 weeks
These paired temperature sensors are used as components of energy meters. They are manufactured with the Pt 100, Pt 500 and Pt 1000 temperature sensing elements. Two or four wire circuits can be connected to the sensors (the internal circuit is always two wire).
344.04KB Download

Datasheet GTP16 / AR | Paired resistance thermometer type TP 16

Product features TP 16 Resistive Paired Probe

The sensors are compatible with energy meters manufactured by SIEMENS, LANDIS + GYR, KAMSTRUP, ITRON, CODEA, COMAC CAl, SENSUS METERING, etc. The sensors are intended for installation in heat sinks. Standard operating temperature range is 0 ° C to 180 ° C

Paired probes type TP 16

BASIC DATA
Sensitive element type 100pt, 500pt, 1000pt
Maximum continuous current 3mA (Pt100); 1,5mA (Pt500); 1mA (Pt1000)
Recommended measurement current 1mA (Pt100); 0,5mA (Pt500); 0,3mA (Pt1000)
Measuring range 0 ° C to 180 ° C or 0 ° C to 150 ° C
soft 2 ° C or 3 ° C
Max. 180 ° C or 150 ° C
Accuracy class of individual sensors B according to EN 60 751
Sensor connection according to the wiring diagram
Maximum overpressure of the thermowell 6,3 MPa

OTHER PARAMETERS
Case length TP 16: 105, 140, 230mm; TP 16A: 97, 133mm
Case diameter TP 16: 6mm + 0,1mm; TP 16A: 3,6 mm + 0,05 mm
Case and thermowell material DIN 1.4301 stainless steel
Connection head type LIMATHERM MA
Connection head material aluminum alloy
Connection head temperature resistance -25 ° C to 100 ° C
Internal wiring resistance

TP 16: 0,015 Ω / 105 mm TP 16A: 0,03Ω / 97 mm 
0,018Ω / 140 mm 0,04 Ω / 133 mm 
0,027Ω / 230mm

Recommended wire section 0,35 to 1,5 mm
Ingress protection IP 54 according to EN 60 529
Isolation resistance > 100 MOhm at 100 V DC, 15 ° C at 35 ° C, relative humidity <85%
Response time TP 16: t 0,5 <5 s (in running water at 0,4 ms -1 ) 
TP 16A: t 0,5 <3 s (in running water at 0,4 ms -1 )
Lengths of thermowells 105, 140, 230mm (TP 16); 88, 124mm (TP 16A)
Thermal thread G 1/2 ", M 20 x 1,5

These products can interest you

Delivery in 3 to 5 weeks
TP 13 Resistive Paired Probe

TP 13 Resistive Paired Probe

These paired temperature sensors are used as components of energy meters. They are made with ...
Delivery in 3 to 5 weeks
TP 15 Resistive Paired Probe

TP 15 Resistive Paired Probe

These paired temperature sensors are used as components of energy meters. They are made with ...
Delivery in 3 to 5 weeks
TP 11E Resistance Paired Probe

TP 11E Resistance Paired Probe

These paired temperature sensors are used as components of energy meters. They are made with ...