ATEX contact probe with stainless steel or dural lug -50 ... + 200 ° C

Delivery in 3 to 5 weeks
  • Temperature sensors TR141Ex.
  • Can be used in potentially explosive environments.
  • Equipment group II, Zone 2 and Zone 22.

Product features ATEX contact probe with stainless steel or dural lug -50 ... + 200 ° C

Temperature sensors work on the principle of defined dependence of the change in resistance of the sensor and the change in temperature. They are not capable of generating sparks, arcs or high surface temperatures. The temperature range for use in potentially explosive environments is limited by the insulation of the cable used and specifically specified in the operating instructions - the specified measuring range should not be exceeded, even for a short time. The power cable can have an outer insulation of PVC, silicone or PTFE (Teflon) and can be shielded or unshielded. In accordance with standard EN 60 529, the sensors meet IP 65 for the insulation of PTFE (Teflon) cables and IP 67 for other power cables.

  • TR 141Ex temperature series- Temperature sensors can be used to measure the surface temperature of solids with a smooth surface. They consist of a cuboid-shaped metal measuring case, which contains a temperature sensing element and a power cable. The metal sensor housing can be made of DIN 1.4301 stainless steel or aluminum alloy (Duralumin). The housing contains a mounting hole for mounting the sensor on the surface to be measured. Sensor wiring can be 2-wire, 3-wire, or 4-wire. The power cable can have external insulation in PVC, silicone or PTFE (Teflon) and is shielded or unshielded. In the case of shielded power cables, the shield is not connected to the housing or the temperature sensing element. The total length of the housing can be chosen in the range from 40 to 60 mm, depending on the design of the sensor housing and the type of power cable.

DECLARATION, CERTIFICATES, CALIBRATION The manufacturer issues a EU declaration of conformity. The declaration is established on the basis of the following certificates, issued by the Ostrava - Radvanice Institute for Physical and Technical Tests:

  • Certificate number TR141Ex FTZÚ 16 ATEX 0145X

Calibration - All temperature sensors undergo the final metrological control, which is carried out by comparison with standards or working gauges. Continuity of standards and working standards is ensured within the meaning of article 5 of Law No. 505/1990 on metrology, as amended.

Sensor TR141Ex
Standard types of sensors Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 500/3850, Pt 1000/3850, NTC 20 kΩ 
- other on request
Measuring range

Y - T2: - 40 ° C ≤ Ta ≤ 230 ° C PTFE cable (teflon) 
T3: - 30 ° C ≤ Ta ≤ 180 ° C SILICON cable 
T5: - 20 ° C ≤ Ta ≤ 95 ° C PVC cable 205 ° C 
T6: - PVC cable at 20 ° C ≤ Ta ≤ 70 ° C

Recommended / maximum DC measurement current

1 mA / 3 mA for sensors with Pt 100 sensor 
0,5 mA / 1,5 mA for sensors with Pt 500 sensor 
0,3 mA / 0,8 mA for sensors with Pt 1000 sensor 
0,3 mA / 1 mA for other sensors 

Recommended / maximum DC input from sensor 0,05 mW / 1 mW for sensors with 20 kΩ NTC sensor  
Precision class Ni sensors: cl. B, Δt = ± (0,4 + 0,007 | t |), for t ≥ 0; Δt = ± (0,4 + 0,028 | t |), for t ≤ 0 in ° C;
Pt: cl sensors B dke EN 60751, Δt = ± (0,3 + 0,005 | t |) in ° C 
NTC 20 kΩ: ± 1 ° C for the range from 0 ° C to 70 ° C
Sensor connection 2 wire, 3 wire, 4 wire
Isolation resistance min. 200 MΩ at 500 V DC, 15 to 35 ° C, maximum relative humidity 80%
Dielectric strength 1 V DC for 000 s, between 1 and 15 ° C, 
maximum relative humidity 80% in accordance with article 6.8.1 in accordance with standard EN 60079-15, as modified
Degree of protection IP 67 for PVC and SILICON cables according to ČSN EN 60529  
IP 65 for PTFE (Teflon) cables according to ČSN EN 60529
Types of power cables and their temperature resistance - 50 to 200 ° C MCBE-AFEP, 2 x 0,34 and 4 x 0,15 mm 2 , SILICONE 
- 40 to 105 ° C FLRYWYW, 2 x 0,35 and 4 x 0,35 mm 2 , PVC up to 105 ° C 
- 30-80 ° C LiYCY 0 x 0,34 mm 2 , PVC, 
- 50 to 260 ° C, PTFE
Cable weight by cable length and type, min. 0,15 kg.


ADDITIONAL DATA

The TR141Ex series
Node 4 Base Dimension 12 x 8 mm
The inside diameter of the housing at the cable sealing position 4,5 mm to 6 mm
Case length 40 to 60 mm
Housing material stainless steel DIN 1.4301, DIN 1.4571, DIN 1.4404
Response time  
(on a smooth surface without paste)

stainless steel τ 0,5 ≤ 10s 
dural τ 0,5 ≤ 8s

These products can interest you