Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

ATEX probe with IP67 connection -30 ... 180 ° C

Reference GTR 011Ex ATEXR

Delivery in 3 to 5 weeks
  • Temperature sensors TR011Ex.
  • Can be used in potentially explosive environments.
  • Equipment group II, Zone 2 and Zone 22.

Product features ATEX probe with IP67 connection -30 ... 180 ° C

The temperature sensors operate on the principle of defined dependence on the change of sensor property and on the temperature change. They are not capable of generating sparks, arcs or high surface temperatures. The temperature range for use in potentially explosive environments is limited by the insulation of the cable used and specifically specified in the user manual - the specified measuring range must not be exceeded, even for a short period. The power cable can be fitted with an outer insulation made of PVC, silicone or PTFE (teflon) and can be shielded or unshielded. In accordance with standard EN 60 529, the sensors respond to IP 65 for the insulation of PTFE (Teflon) cables and to IP 67 for other power cables.

The temperature sensors are designed to operate in a chemically non-aggressive environment, the use must be chosen according to the temperature and the chemical resistance of the case and the power cable.

  • TR 011 series temperature sensor- The sensors can be used to measure the temperature of gaseous and liquid substances in pipes or air conditioning pipes or separately to measure the temperature of solids. They consist of a 6 mm, 7 to 10 mm or 12 mm diameter metal measuring box, containing a temperature sensor and a power cable. The metal sensor housing can be made of stainless steel DIN 1.4301, DIN 1.4404, DIN 1.4571. The fixed part of the housing is a mounting fitting with different thread sizes and an OK hexagon, allowing direct installation in the measurement location without the use of a thermowell. Sensor wiring can be 2-wire, 3-wire, or 4-wire. In the case of shielded power cables, the shield is not connected to the housing or the temperature sensing element. The length of the housing can be chosen in the range from 40 to 400 mm,

DECLARATION, CERTIFICATION, CALIBRATION

The manufacturer issues a EU declaration of conformity

The declaration is established on the basis of the following certificates, issued by the Ostrava - Radvanice Institute for Physical and Technical Tests:

  • TR011Ex Appendix N ° 2 to certificate n ° FTZÚ 07 ATEX 0143X

Calibration - All temperature sensors undergo the final metrological control, which is carried out by comparison with standards or working gauges. Continuity of standards and working standards is ensured within the meaning of article 5 of Law No. 505/1990 on metrology, as amended. 

Sensor TR 011 ATEX series
Standard types of sensors Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 1000/3850, NTC 20 kΩ  
- other on request 
Measuring range

Y - T2: - 40 ° C ≤ Ta ≤ 230 ° C PTFE cable (teflon) 
T3: - 30 ° C ≤ Ta ≤ 180 ° C SILIKON cable  
T5: - 20 ° C ≤ Ta ≤ 95 ° C PVC at 205 ° C 
T6: - 20 ° C ≤ Ta ≤ 70 ° C PVC cable 

Recommended / maximum DC measurement current 1 mA / 3 mA for sensors with Pt 100 sensor 
0,5 mA / 1,5 mA for sensors with Pt 500 sensor 
0,3 mA / 0,8 mA for sensors with Pt 1000 sensor 
0,3 mA / 1 mA for other sensors
Recommended / maximum DC input from sensor 0,05 mW / 1 mW for sensors with 20 kΩ NTC sensor
Precision class Ni sensors: cl. B, Δt = ± (0,4 + 0,007 t), for t ≥ 0; Δt = ± (0,4 + 0,028 | t |), for t ≤ 0 in ° C; 
Pt: cl sensors B dke EN 60 751, Δt = ± (0,3 + 0,005 | t |) in ° C 
NTC 20 kΩ: ± 1 ° C for the range from 0 ° C to 70 ° C
Sensor connection 2 wire, 3 wire, 4 wire
Isolation resistance min. 200 MΩ at 500 V DC, between 15 and 35 ° C, maximum relative humidity of 80%
Dielectric strength 1 V DC for 000 s, between 1 and 15 ° C, 
maximum relative humidity 80% according to clause 6.8.1 according to ČSN EN 60079-15
Degree of protection

IP 67 for PVC and SILICON cables according to ČSN EN 60529 
IP 65 for PTFE (Teflon) cables according to ČSN EN 60529

Types of power cables and their temperature resistance - MCBE-AFEP 50 at 200 ° C, 2 x 0,34 and 4 x 0,15 mm 2 , SILICON 
FLRYWYW 40 to 105 ° C, 2 x 035 and 4 x 0,35 mm 2 , PVC up to 105 ° C 
- 30 to 80 ° C LiYCY 0 x 0,34 mm 2 ,PVC 
- 50 to 260 ° C PTFE
The weight  depending on cable length, min. 0,15 kg.


ADDITIONAL DATA

TR011 Ex Series
Protective tube diameter Standard 6 mm - Others on request (7, 8, 9, 10, 11 and 12mm)
Connection Standard M10x1.5mm - Other on customer request
Length of the stem 40 to 400 mm
Material of the stem stainless steel DIN 1.4301, DIN 1.4571, DIN 1.4404
Type de fil at the customer's request
Response time (in running water 0,2 ms -1)
0,5 <9 s, τ 0,9 ≤ 20 s for  housing Ø 6 mm 
τ 0,5 <14 s, τ 0,9 ≤ 35 s for housing Ø 7 to 8 mm 
τ 0,5 <25 s, τ 0,9 ≤ 60 s for Ø 9 to 10 mm 
τ 0,5 <35 s, τ 0,9 ≤ 80 s for Ø 12 mm

These products can interest you