Ir al contenido
guilcor.com
  • Inicio
  • Sondas
    Smooth tube probe

    Tubo liso

    Refrigerador, bomba de calor, horno, congelador, calentador de agua
    Contact probe

    Contacto

    Tubería, superficie de tubería, placa calefactora
    Slot probe

    Ranura

    Motor, alternador, bobinado, estator
    Head connection probe

    Cabezal de conexión

    Caldera, bomba de calor, aire acondicionado, salas técnicas, ventilación
    Waterproof probe

    Impermeable

    Aire acondicionado, ventilación, refrigeración, almacenamiento en frío, conductos
    Stick-in probe

    Inserción

    Horno, cocción, equipos de procesamiento de alimentos
    Winding probe

    Bobinado

    Motor, alternador, transformador, bobinado, estator
    Ambient probe

    Ambiente

    Caldera, bomba de calor, aire acondicionado, salas técnicas, ventilación
    Thread probe

    Con racor

    Máquina de café, caldera, vapor, fluido presurizado
    Jacketed probe

    Envainadas

    Instalaciones industriales, aplicaciones de alta resistencia
    Bayonet probe

    Bayoneta

    Moldeo de plástico, herramientas, máquina de moldeo por inyección, motor, alternador
    PCBA Design

    Diseño de PCBA

    Aplicación específica, electrónica embebida, placas electrónicas personalizadas
  • Sensores

    RTD

    Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Pt5000, Ni100, Ni120, Cu10, Cu50, Balco

    PTC

    KTY81-110, KTY81-210, KTY83-110, KTY84-130, PTC130, Silistor, TFPT, MZ6, MZ8, MZ9

    1-Wire

    DS18B20, DS18S20, DS1822, DS28EA00, DS18B20-PAR, DS1920, DS2438, DS1835...

    Termopar

    B, E, J, K, N, R, S, T, C, D, G

    UART

    MLX90614, MLX90615, GY-906, DHT11, DHT22, AM2302, SHT75, SHT85, RS232, RS485

    SPI

    MAX6675, MAX31855, MAX31856, MCP3208, TMP125, TMP121, ADT7310, LTC2983...

    NTC

    1kΩ, 2kΩ, 3kΩ, 5kΩ, 10kΩ, 15kΩ, 20kΩ, 30kΩ, 50kΩ, 100kΩ, 200kΩ, 470kΩ, 1MΩ

    I²C

    TMP102, TMP117, LM75, LM73, MCP9808, MCP9600, SHT31, SHTC3, SHT85, BME280, BME688, HTU21D, HDC1080, Si7051, ADT7410, STTS751, TCN75A...
  • Sobre nosotros
  • 0
  • 0
  • Síganos
  • English (US) Français Español
  • Iniciar sesión
  • Contáctenos
guilcor.com
  • 0
  • 0
    • Inicio
    • Sondas
    • Sensores
    • Sobre nosotros
  • Síganos
  • English (US) Français Español
  • Iniciar sesión
  • Contáctenos

 MZ6 
 Temperature sensors 

Durable PTC sensor for industrial equipment and embedded applications, ensuring reliable thermal protection.

 Maximum precision
+/- 5°K

 Minimum temperature
-20°C

 Maximum temperature
+180°C

 Minimum dimensions
2,5 x 10

 Response time
Medium

 Self-heating
Low

 Price
Medium

Drift
Low

What is a MZ6 sensor ?Operating principleTechnical specificationsWiring configurationSelf-heatingApplication areas

What is a MZ6 sensor ?


The MZ6 is a threshold PTC thermistor used as a thermal protection sensor in motors, transformers, and power systems.

Its resistance remains low and stable up to a specific switching temperature (typically between 60 °C and 180 °C, depending on the version), then increases sharply, indicating overheating.

It complies with DIN 44081 / 44082 standards, ensuring its interchangeability with other protection PTCs.

Operating principle


Under the nominal temperature (Tₙ), the resistance is low (about 150 Ω).

As soon as the temperature reaches the threshold, the resistance increases exponentially to several tens of kilo-ohms within a few degrees.

This transition is detected by a PTC control relay, which cuts off the control circuit to protect the system.

Temperature (°C) Typical resistance (Ω)
20 150
80 160
100 170
120 (Tₙ) 1650
140 4500
160 10 000
180 20 000

🧠 This sharp trigger curve makes it a reliable safety component for electromechanical systems.

Technical specifications


Parameter Typical value
Nominal resistance (Tₙ) 60°C to 180°C depending on model
Resistance at 25 °C 150 Ω ±20 %
Resistance to Tₙ  ≥ 1650 Ω
Maximum measurement current. 2,5 mA
Electrical isolation ≥ 2,5 kV
Response time 3 to 5 s
Case Epoxy, glass or ceramic

Wiring Configuration


Type Description

Precision

2-wire

Series assembly in the detection circuit.

✅ Standard

Multiple chain

Several MZ6 in series to monitor multiple engine zones.

🏆 Industrial

Integrated

Stuck or molded in the motor winding.

💡 Direct thermoprotection

Self-heating


The measurement current being limited to a maximum of 2.5 mA, self-heating is negligible, ensuring purely external temperature detection.

Application areas


⚙️ Thermal protection of three-phase motors

🔋 Monitoring of transformers and power inductors

🚗 Battery protection systems and variable speed drives

🧱 Industrial applications compliant with DIN 44081/82

🧠 Sensors integrated into thermal cut-off relays



Should I choose a MZ6 sensor ?

Strengths points

  • 🧱 Robust and proven
    → The MZ6 has been an industrial standard for decades — reliable, simple, and fully compatible with DIN 44081/82 detection modules.
  • ⚡ Quick and clear trigger
    → Its steep resistance curve ensures instant and reproducible overheating detection, without complex electronics.
  • 🔩 Adaptable to all motor windings
    → Thanks to its compact size and 2.5 kV insulation, it can be directly integrated into the winding or molded into the resin.
MZ6 Sensors

Weaknesses points

  • 🌡️ Non-linear
    → The MZ6 is not suitable for continuous temperature measurement: it only provides a threshold exceedance signal.
  • 🔋 Limited measurement current
    → A current greater than 2.5 mA can distort the triggering temperature and may even damage the component.
  • 💡 Requires a dedicated PTC relay
  • → To function properly, the sensor must be paired with a compatible DIN detection module, which adds additional cost and bulk.

Useful information

Here is some useful information regarding the MZ6 sensors.

The MZ6 sensors comply with DIN 44081 / 44082 standards, which define their switching characteristics, tolerance, and dynamic behavior.

They are not classified as A/B/C like linear PTCs, but according to the nominal triggering temperature (Tₙ).

Type MZ6
Nominal temperature (Tₙ)
Tolerance (Tₙ)
Resistance at 25 °C (R25)
Resistance to Tₙ
Applicable standard
MZ6-60 60 °C ±5 K 150 Ω ±20 % ≥ 1650 Ω DIN 44081
MZ6-80 80 °C ±5 K 150 Ω ±20 % ≥ 1650 Ω DIN 44081
MZ6-120 120 °C ±5 K 150 Ω ±20 % ≥ 1650 Ω DIN 44081
MZ6-150 150 °C ±5 K 150 Ω ±20 % ≥ 1650 Ω DIN 44082
MZ6-180 180 °C ±5 K 150 Ω ±20 % ≥ 1650 Ω DIN 44082

🔹 Remarks:

  • All models exhibit a nearly constant resistance (<200 Ω) up to about 20 K before Tₙ.
  • Beyond the threshold, the resistance increases exponentially (up to several tens of kΩ).
  • The tolerances ensure complete interchangeability between manufacturers compliant with DIN.

The MZ6 exhibit a bistable threshold behavior.

Their evolution can be represented by two distinct regimes: linear before Tₙ, exponential after Tₙ.

R(T) = { R₀ [1 + α(T - 25)] for T < T_N 

​ ​{ R_N × e^{β(T - T_N)} for T ≥ T_N

with: 

• R₀ = 150 Ω: resistance at 25°C

• α ≈ 3 × 10⁻³ K⁻¹

• R_N = 1650 Ω: nominal resistance at the threshold

• β ≈ 0.25 K⁻¹


🔹 Example 1: normal regime (T = 80 °C, threshold 120 °C)

R(80) = 150 × [1 + 3×10⁻³ × (80 - 25)] = 150 × 1.165 = 174.8 Ω

✅ Result: the engine is functioning normally, no overheating.


🔹 Example 2: overheating (T = 140 °C)

R(140) = 1650 × e^(0.25 × (140 - 120)) = 1650 × e^5 ≈ 1650 × 148.4 = 244,000 Ω

✅ Result: the resistance rises to ≈ 240 kΩ, instantaneous cutoff signal.


🔹 Practical notes

The MZ6 acts as a progressive thermal switch.

It does not allow for any precise temperature measurement, but ensures reliable and reproducible threshold detection.

The R(T) curve remains stable after several thousand thermal cycles.

The MZ6 is used in a protection circuit via a PTC detection relay.

Multiple sensors can be connected in series to monitor different areas of the same motor.

Component Function
MZ6 (Threshold PTC)
Nominal temperature sensor
PTC detection module / Thermal relay
Threshold exceedance triggering
Power Supply (24 V DC)
Feed the control circuit
Power contactor / relay
Turn off the engine or the protected system
🔹 Functional diagram (ASCII)

+24 V │ [PTC Detection Relay] │ ├────┴────┐ │ │ [MZ6-120] [MZ6-120] (in series on 2 windings) │ │ └────┬────┘ │ GND

🔹 Operating Principle

1️⃣ Each MZ6 sensor is inserted into a critical area of the engine.

2️⃣ As long as T < Tₙ, the resistance remains low → PTC relay closed → normal operation.

3️⃣ As soon as a sensor reaches its threshold → resistance > 1.5 kΩ → relay opens the circuit → immediate engine shutdown.

🔹 Best Practices

  • 🧩 Use sensors with the same Tₙ in a series chain.
  • ⚡ Never exceed 2.5 mA of test current.
  • 💧 Avoid direct contact with humid environments (molding or varnishing recommended).
  • 🧲 Use a DIN 44081/82 certified relay to ensure compatibility.
  • 🔄 Replace all PTCs during preventive maintenance to maintain thermal consistency.

 We integrate any sensor into any probe 

Smooth tube probe

 Smooth tube 

Waterproof probe

 Waterproof

Bayonet probe

 Bayonet

Slot probe

 Slot

Ambient probe

 Atmosphere

Head connection probe

Termal block

Stick-in probe

Stick-in

Thread probe

Thread

Contact probe

Contact

Jacketed probe

Jacketed

PCBA Design

PCBA design

Winding probe

Winding

More than 1,000,000 probes delivered in 2025

Contact us for a personalized offer

Contact Us

Need an MZ6 sensor?

Whether you need a few parts for a prototype or several hundred for a production line, we support you at every step.


Submit
Enlaces útiles
  • Inicio
  • Sobre nosotros
  • Empleos
  • Avisos legales
  • Política de privacidad
  • Contáctenos
Sobre nosotros

At Guilcor, our mission is clear: to provide every client with a measurement solution perfectly suited to their specific needs.With full control over design and manufacturing, we ensure the precision and reliability of our sensors in even the most demanding environments.

La excelencia técnica y la satisfacción del cliente están en el corazón de todo lo que hacemos.

Contáctenos
  • Contáctenos
  • contact@guilcor.com
Síganos