Se rendre au contenu
guilcor.com
  • Page d'accueil
  • Sondes
    Smooth tube probe

    Tube lisse

    Réfrigérateur, pompe à chaleur, four, congélateur, chauffe-eau
    Contact probe

    Contact

    Tuyau, surface de tuyau, plaque de chauffage
    Slot probe

    D'Encoche

    Moteur, alternateur, enroulement, stator
    Head connection probe

    Avec Bornier

    Chaudière, pompe à chaleur, climatisation, locaux techniques, ventilation
    Waterproof probe

    Étanche

    Climatisation, ventilation, réfrigération, stockage à froid, conduits
    Stick-in probe

    À Piquer

    Four, cuisson, équipements alimentaire
    Winding probe

    Bobinage

    Moteur, alternateur, transformateur, enroulement, stator
    Ambient probe

    Ambiance

    Chaudière, pompe à chaleur, climatisation, locaux techniques, ventilation
    Thread probe

    Avec Raccord

    Machine à café, chaudière, vapeur, fluide sous pression
    Jacketed probe

    Chemisée

    Installations industrielles, applications lourdes
    Bayonet probe

    Baïonnette

    Moulage plastique, outillage, machine de moulage par injection, moteur, alternateur
    PCBA Design

    PCB Design

    Application spécifique, électronique embarquée, cartes électroniques sur mesure
  • Capteurs

    RTD

    Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Pt5000, Ni100, Ni120, Cu10, Cu50, Balco...

    PTC

    KTY81-110, KTY81-210, KTY83-110, KTY84-130, PTC130, Silistor, TFPT, MZ6, MZ8, MZ9...

    1-Wire

    DS18B20, DS18S20, DS1822, DS28EA00, DS18B20-PAR, DS1920, DS2438, DS1825...

    Thermocouple

    B, E, J, K, N, R, S, T, C, D, G

    UART

    MLX90614, MLX90615, GY-906, DHT11, DHT22, AM2302, SHT75, SHT85, RS232, RS485

    SPI

    MAX6675, MAX31855, MAX31856, MCP3208, TMP125, TMP121, ADT7310, LTC2983...

    NTC

    1kΩ, 2kΩ, 3kΩ, 5kΩ, 10kΩ, 15kΩ, 20kΩ, 30kΩ, 50kΩ, 100kΩ, 200kΩ, 470kΩ, 1MΩ...

    I²C

    TMP102, TMP117, TMP119, LM75, LM73, MCP9808, MCP9600, SHT31, SHTC3, BME280, BME688, HTU21D, HDC1080, Si7051, ADT7410, STTS751, TCN75A
  • Entreprise
  • 0
  • 0
  • Suivez-nous
  • English (US) Français Italiano Español
  • Se connecter
  • Contactez-nous
guilcor.com
  • 0
  • 0
    • Page d'accueil
    • Sondes
    • Capteurs
    • Entreprise
  • Suivez-nous
  • English (US) Français Italiano Español
  • Se connecter
  • Contactez-nous

 Type S 
 Temperature sensors 

Premium thermocouple offering excellent accuracy and stability for high-temperature measurement up to 1600 °C.

 Maximum precision
+/- 1,0°K

 Minimum temperature
-50°C

 Maximum temperature
+1760°C

 Minimum dimensions
0,5 x 50 x 5

 Response time
Low

 Internal Resistance
High

 Linearity
High

Price
High

What is a Type S thermocouple ?Operating principleTechnical specificationsVoltage / Temperature CurveCompatibility / CompensationApplication areas

What is a Type S thermocouple ?


The type S thermocouple is a very high-precision sensor used in extreme environments and reference laboratories.

Composed of a pure platinum (Pt) wire and a platinum–rhodium (Pt-10%Rh) wire, it offers exceptional thermal stability and remarkable chemical resistance.

It is the preferred thermocouple for scientific, medical, and industrial applications requiring reliable long-term temperature measurement.

Operating principle


Like all thermocouples, type S relies on the Seebeck effect: the junction between two different metals produces a voltage proportional to the temperature difference.

E = S × (T_hot - T_cold)

For type S:

S ≈ 10 µV/°C at 1,000 °C

Its output voltage is almost identical to that of type R, but type S is slightly more chemically stable.

Technical specifications


Parameter
Typical Value
Measurement range −50 °C → +1 760 °C
Sensitivity 10 µV/°F at 1,000 °C
Tension at 100 °C ≈ 11,35 mV
Tension at 500 °C ≈ 16,73 mV
Tension at 1000 °C ≈ 18,69 mV
Oxidation resistance Excellent
Response time (6 mm diameter sheath) 5 to 10 s
Reference standard IEC 60584-1, ASTM E230

Voltage / Temperature Curve


(Reference: Cold junction at 0 °C — IEC 60584-1 standard)

The type S curve is extremely regular across the entire measurement range.

It is almost identical to that of type R, but with even greater chemical and thermal stability.

📈 General behavior:

  • From 0 to 1,760 °C → increasing voltage (~0 to +18.7 mV)
  • Average slope: ≈ 10 µV/°C at 1,000 °C
  • Drift is nearly zero even after several hundred hours of use

💡 Type S is often chosen as the primary calibration thermocouple in national laboratories.

Compatibility / Compensation


The S type requires a cold weld compensation, typically integrated into precision measurement systems.

It is compatible with professional instruments (AD8495-S, MAX31855-S, LTC2983) and calibration standards.

Its exceptional stability makes it ideal for reference measurements, furnace controls, or high-temperature metrology.

Application areas


🔬 Reference and Metrology Laboratories

🧱 Glass, Ceramics, and Metal Melting Industry

🧪 High-Precision Chemical and Thermal Analysis

⚙️ Medical Equipment and Scientific Research





Should I choose a Type S thermocouple?

Strengths points

  • ⚗️ Absolute reference sensor
    → Employed in metrology laboratories and calibration chains, he ensures exceptional reproducibility.
  • 🔥 Exceptional heat resistance→ It withstands temperatures exceeding 1,700 °C without significant drift — ideal for melting furnaces.
  • 🧱 Noble and stable chemistry
    → Platinum and rhodium provide almost total immunity to oxidation and corrosion.
Type S Thermocouple sensors

Weaknesses points

  • 💸 Significant investment
    → Its very high cost limits it to scientific and critical uses, not to regular production.
  • 🐢 Slow response
    → The ceramic or alumina sheath provides good protection but significantly slows down the thermal response.
  • 📉 Weak signal
    → The generated tension remains modest, requiring a very precise differential amplifier.

Useful information

Here is some useful information regarding Type S thermocouples.

(Reference: cold junction at 0 °C — IEC 60584-1 standard)
Temperature (°C) Tension (mV) Temperature (°C) Tension (mV)
0 0,000 1 200 12,016
200 1,426 1 400 14,308
400 3,138 1 500 15,287
600 4,913 1 600 16,276
800 6,761 1 700 17,194
1 000 8,585 1 760 17,690
💡 The S type maintains remarkable accuracy across its entire range of use, even after numerous thermal cycles.
Class Tolerance (K) Usage area
Description
Class 1 ±1,0 K ou ±0,25 % 0 → +1 600 °C High precision
Class 2 ±1,5 K ou ±0,5 % 0 → +1 600 °C Industrial standard
Class 3 — Not applicable No class 3 for type S

🔹 Even class 2 ensures an accuracy of the order of one-tenth of a degree at high temperature.

Example 1 – Calculation of the generated voltage

Measured temperature: 1,200 °C

Cold weld: 0 °C

E = 12,016 mV

Cold welding at 25 °C → correction voltage ≈ 0.15 mV :

E_measured = 12,016 - 0,15 = 11,866 mV

✅ Actual voltage ≈ 11.87 mV


Example 2 – Calculating temperature from a measured voltage

Measured voltage: 16.276 mV (cold joint at 0 °C)

→ By consulting the IEC table:

T=1600°C

✅ Measured temperature ≈ 1,600 °C

The type S thermocouple generates a low voltage and requires highly stable and precise reading electronics.

🔹 Typical components

Component
Function
Thermocouple type S (Pt10Rh / Pt) Generate the Seebeck voltage
Differential amplifier (INA333, AD8495-S)
Amplify the signal µV → V
Compensation sensor (NTC or integrated)
Correct the temperature of the cold weld
ADC 24 bits Convert the amplified voltage
Microcontroller / Calibration System
Calculate the temperature according to the IEC table
🔹 Functional diagram (ASCII)

[HOT JUNCTION]──(Thermocouple S)──[AMPLIFIER]──[ADC]──[µCONTROLLER] │ └──(Compensation sensor)

💡 Type S is used in analytical furnaces, national laboratories, and applications where precision allows for no approximation.

 We integrate any sensor into any probe 

Smooth tube probe

 Smooth tube 

Waterproof probe

 Waterproof

Bayonet probe

 Bayonet

Slot probe

 Slot

Ambient probe

 Atmosphere

Head connection probe

Termal block

Stick-in probe

Stick-in

Thread probe

Thread

Contact probe

Contact

Jacketed probe

Jacketed

PCBA Design

PCBA design

Winding probe

Winding

Plus de 1 000 000 sondes livrées en 2025

Contactez-nous pour une offre personnalisée

Contactez-nous

Need a Type S thermocouple?

Que vous ayez besoin de quelques pièces pour un prototype ou de plusieurs centaines pour une ligne de production, nous vous accompagnons à chaque étape.


Soumettre
Liens utiles
  • Accueil
  • À propos de nous
  • Emplois
  • Mentions légales
  • Politique de confidentialité
  • Contactez-nous
À propos de nous

Chez Guilcor, notre mission est claire : fournir à chaque client une solution de mesure parfaitement adaptée à ses besoins spécifiques. Grâce à une maîtrise totale de la conception et de la fabrication, nous garantissons la précision et la fiabilité de nos capteurs, même dans les environnements les plus exigeants.

L'excellence technique et la satisfaction client sont au cœur de tout ce que nous faisons.

Rejoignez-nous
  • Contactez-nous
  • contact@guilcor.com
Suivez-nous

Politique de cookies

Nous utilisons des cookies pour vous offrir une meilleure expérience utilisateur sur ce site web. Politique de cookies

Que les essentiels Je suis d'accord