Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

TSA TEMPERATURE SWITCHES

Reference GTSAR

Delivery in 3 to 5 weeks
  • TSA 220 A - to detect the temperature around the switch; temperature probe in a 60 mm long metal rod,
  • TSA 220 K - temperature sensor in a metal rod for use in air conditioners or pipes; comes with a plastic holder. As an accessory, a stainless steel well or a metal support can be supplied with the sensor,
  • TSA 220 C - the temperature sensor in the housing TG 8 with a length of 40 mm is taken out through a cable with a length of 1 m (a different length of the cable or the housing, or another type of sensor must be specified in the order),
  • TSA 220 P - enclosed version for piping, temperature probe in a metal measuring case placed in a protective case made of SILICONE and SILAMIDE materials; delivered with fixing tape (length 40 cm) and cap.
367.45KB Download

GTSAR technical sheet | TSA TEMPERATURE SWITCHES

Product features TSA TEMPERATURE SWITCHES

TSA temperature switches are designed as two-state controllers (ON / OFF control), which compare the setpoint and instantaneous temperature and allow switching of galvanically isolated relay contacts when the setpoint temperature value is reached. The desired temperature is set using a potentiometer.

In terms of sensor location and use of switches, the following designs are distinguished:

TSA 220 A - to detect the temperature around the switch; temperature probe in a 60 mm long metal rod,

TSA 220 K - temperature sensor in a metal rod for use in air conditioners or pipes; comes with a plastic holder. As an accessory, a stainless steel well or a metal support can be supplied with the sensor,

TSA 220 C - the temperature sensor in the housing TG 8 with a length of 40 mm is taken out through a cable with a length of 1 m (a different length of the cable or the housing, or another type of sensor must be specified in the order),

TSA 220 P - enclosed version for piping, temperature probe in a metal measuring case placed in a protective case made of SILICONE and SILAMIDE materials; delivered with fixing tape (length 40 cm) and cap.

Standard temperature ranges in which the required temperature can be set are shown in the technical parameters table. For TSA 220 A switches, the maximum authorized operating temperature is 70 ° C, for TSA 220 P switches 110 ° C, for TSA 220 K switches, for applications above 140 ° C, a variant with a rod elongated by 60 mm and a metal central support is provided.

The switches are designed to operate in a chemically non-aggressive environment.

ACCESSORIES

stainless steel sump JS 130

metal support K 120

for switch type TSA 220 P it is possible to supply thermal conductive paste up to 200 ° C, 5 g

sliding connection - for setting different immersion lengths of the temperature sensor rod (for switch type TSA 220K)

DECLARATION, CERTIFICATION, CALIBRATION

EU Declaration of Conformity - according to Law 22/1997 Coll. on the technical requirements applicable to the products, as amended.

Calibration - All production undergoes an output metrological control, which is carried out by comparison with standards or with working gauges. The traceability of standards and working calibers is ensured within the meaning of §5 of Law No. 505/1990 on metrology. The manufacturer offers the possibility of supplying calibrated sensors in the laboratory of SENSIT sro (according to the requirements of ČSN EN ISO / IEC 17025) or in AKL.

E OF BASE
Sensor type
Standard temperature setting ranges
 
 
 
 
 
 
 
Supply voltage
Maximum voltage / switching current
Error when setting the desired temperature
Standard hysteresis
Connection switch
Recommended conductor cross-section
Head material
Head dimensions
Temperature around the head
Degree of protection
Socket type
Mass
 
TSA 220A
Standard rod length L1
Diameter of the stem
Material of the stem
Switch assembly
Maximum temperature measurement range
 
TSA 220K
Rod length L1
Diameter of the stem
Material of the stem
Switch assembly
Maximum temperature measurement range
 
TSA 220C
Standard sensor type
Case diameter
Housing
Power cord
Sensor cover
Switch assembly
Maximum temperature measurement range
 
TSA 220P
Measuring sleeve material
Protective case material
Switch assembly
Standard band length
Minimum pipe diameter
 
By 1000/5000
-25 To 15 ° C
0 to 40 ° C
0 to 80 ° C
10 to 34 ° C
20 to 60 ° C
40 to 80 ° C
60 to 140 ° C
120 to 160 ° C
230 V / Hz 50
250 V AC / 6 A
± 0,5 ° C
2°C
according to the wiring diagram
From 0,35 to 1,5 mm 2
LEXAN 500R
62 x 62 x 95 mm (including control button)
-25 To 70 ° C
IP 54 according to ČSN EN 60 529, as amended
M16x1,5
depending on design, min. 0,2 kg
 
 
60 millimeters
6 0,2 + mm
DIN 1.4301 stainless steel
using a metal wall bracket
-25 To 70 ° C
 
 
70, 120, 180, 240 mm
6 0,2 + mm
DIN 1.4301 stainless steel
using a plastic or stainless steel center bracket or a stainless steel sink
-25 to 200 ° C (above 140 ° C extended rod)
 
 
TG 8 - 40, cable 1 m
5,7 ± 0,1 mm
DIN 1.4301 stainless steel
shielded silicone 2 x 0,34 mm 2
IP 67 according to ČSN EN 60 529, as amended
using a metal wall bracket
-30 To 200 ° C
 
 
brass
SILICONE and SILAMIDE
using fixing tape with a cap
40cm
20 mm