TP 11E Resistance Paired Probe
These paired temperature sensors are used as components of energy meters. They are made with ...
BASIC DATA | |
Sensitive element type | P1, Pt100, Pt500 |
Maximum continuous current | 3mA (Pt100); 1,5mA (Pt500); 1mA (Pt1000) |
Recommended measurement current | 1mA (Pt100); 0,5mA (Pt500); 0,3mA (Pt1000) |
Measuring range | 0 to 180 ° C |
soft | 2 or 3 ° C |
Max. | 180 ° C |
Accuracy class of individual sensors | B according to EN 60 751 |
Sensor connection | according to the wiring diagram |
OTHER PARAMETERS | |
TP 15: 65*, 105, 140, 230mm | |
The standard length of the case | TP 15A: 120/91; 175/146 mm |
TP 15B: 120/91; 175/146 mm | |
Diameter of the case | 6 mm (with tolerance d10 in the length 50 mm) |
Case and thernowell material | DIN 1.4301 stainless steel |
Input cable | 2 x 2mm unshielded 0,5-wire silicone 2 Silicone 4 unshielded wires 4 x 0,25 mm 2 |
Cable length | according to EN 1434-2, art. 3.3.4, chart 2 |
Wire resistance | 0,07 per 1 m of 2-wire cable |
Cable temperature resistance | -25 to 180 ° C |
Ingress protection | IP 67 in accordance with EN 60 529 |
Isolation resistance | > 100 MOhm at 100 V DC, 15 to 35 ° C, relative humidity <80% |
Response time | t 0,5 <6 s (in white water at 0,4 ms -1 ) |
Lengths of thermowells | 65*, 105, 140, 230mm (TP 15); 91, 146mm (TP 15A) |
Thermal thread | G1 / 2 ", M 20 x 1,5 |
Maximum overpressure of the thermowell | 6,3 MPa |