The temperature sensors operate on the principle of defined dependence on the change of sensor property and on the temperature change. They are not capable of generating sparks, arcs or high surface temperatures. The temperature range for use in potentially explosive environments is limited by the insulation of the cable used and specified in the user manual - the specified measuring range must not be exceeded, even for a short period. The power cable can be fitted with an outer insulation made of PVC, silicone or PTFE (teflon) and can be shielded or unshielded. In accordance with standard EN 60 529, the sensors respond to IP 65 for the insulation of PTFE (Teflon) cables and to IP 67 for other power cables.
The temperature sensors are designed to operate in a chemically non-aggressive environment, the use must be chosen according to the temperature and the chemical resistance of the case and the power cable.
- Probes temperature GTG8ExR Series - In combination with the thermowell or central support JTG8, supplied as accessories, the probes can be used to measure the temperature of gaseous and liquid substances in pipes or air conditioning pipes or separately to measure the temperature of solids.
DECLARATION, CERTIFICATION, CALIBRATION
The manufacturer issues a EU declaration of conformity. The declaration is established on the basis of the following certificates, issued by the Ostrava - Radvanice Institute for Physical and Technical Tests:
- TG8Ex Appendix N ° 2 to the certificate number FTZÚ 07 ATEX 0142X
Calibration - The final metrological control - comparison with standards or working instruments - is carried out for all products. The continuity of standards and work measurement instruments is ensured within the meaning of article 5 of Law No. 505/1990 on metrology.
Sensor | GTG8ExR |
Standard types of sensors |
Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 500/3850, Pt 1000/3850, NTC 20 kΩ |
Measuring range | Y - T2: - 40 ° C ≤ Ta ≤ 230 ° C PTFE cable (teflon) T3: - 30 ° C ≤ Ta ≤ 180 ° C SILIKON cable T5: - 20 ° C ≤ Ta ≤ 95 ° C PVC at 205 ° C T6: - 20 ° C ≤ Ta ≤ 70 ° C PVC cable |
Recommended / maximum DC measurement current |
1 mA / 3 mA for sensors with Pt 100 sensor |
Recommended / maximum DC input from sensor | 0,05 mW / 1 mW for sensors with 20kΩ NTC sensor |
Precision class | Ni sensors: cl. B, Δt = ± (0,4 + 0,007 | t |), for t ≥ 0; Δt = ± (0,4 + 0,028 | t |), for t ≤ 0 in ° C; Pt: cl sensors B dke EN 60751, Δt = ± (0,3 + 0,005 | t |) in ° C NTC 20 kΩ: ± 1 ° C for the range from 0 ° C to 70 ° C |
Sensor connection | 2 wire, 3 wire, 4 wire |
Isolation resistance | min. 200 MΩ at 500 V DC, between 15 and 35 ° C, maximum relative humidity of 80% |
Dielectric strength | 1 V DC for 000 s, between 1 and 15 ° C, maximum relative humidity 80% in accordance with article 6.8.1 in accordance with standard EN 60079-15, as modified |
Degree of protection | IP 67 for PVC and SILICON cables IP 65 for PTFE (Teflon) cables |
Types of power cables and their temperature dependence | - MCBE-AFEP 50 at 200 ° C, 2 x 0,34 and 4 x 0,15 mm 2 , SILICON - FLRYWYW 40 to 105 ° C, 2 x 035 and 4 x 0,35 mm 2 , PVC up to 105 ° C - 30 to 80 ° C LiYCY 0 x 0,34 mm 2 ,PVC - 50 to 260 ° C PTFE |
Cable weight | by cable length and type, min. 0,15 kg |
ADDITIONAL DATA
GTG8ExR Series | |
Length of the stem | 40 to 400 mm |
Diameter of the stem | 5,7 mm, 6 mm, 7 to 10 mm, 12 mm |
Material of the stem | stainless steel DIN 1.4301, DIN 1.4571, DIN 1.4404 |
Response time (in running water 0,2 ms -1) |
τ 0,5 ≤ 5s, τ 0,9 ≤ 12 s for a diameter of 5,7 mm τ 0,5 <9 s, τ 0,9 ≤ 20 s for a diameter of 6 mm τ 0,5 <14 s, τ 0, 9 ≤ 35 s for a diameter of 7 to 8 mm τ 0,5 <25 s, τ 0,9 ≤ 60 s for a diameter of 9 to 10 mm τ 0,5 <35 s, τ 0,9 ≤ 80 s for a diameter of 12 mm |