TECHNICAL DATA

ATEX certified transmitter temperature and humidity.

For use in potentially explosive areas.

Relative humidity and temperature transmitter with remote probe on 1 meter cable.

The measured values ​​are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

ATEX certification for use in explosive atmospheres. 

INCLUDED IN DELIVERY

  • AR004611
  • Manuel
  • Traceable calibration certificate
  • Free Tsensor configuration software


MEASURED VALUES

- Temperature
- Relative humidity
- Calculated values ​​(dew point, etc.)

Relative humidity range: 0 to 100%

Relative humidity measurement uncertainty: ±2.5% relative humidity from 5 to 95% at 23°C

Temperature measurement uncertainty: ±0.4°C from -30 to +100°C
±0.4% of reading above +100°C

Units available: degrees Celsius, Fahrenheit

Dew point measurement uncertainty and range: ±1.5°C at ambient temperature T<25°C and RH>30%
Range -60 to +80 ° C

Absolute humidity uncertainty and range: ±1.5g/m3 at ambient temperature T < 25 °C
Range 0 to 400 g/m3

Uncertainty and specific enthalpy range: ±2g/kg at ambient temperature T < 35°C
Range 0 to 550 g/kg

Uncertainty and range of mixture ratio: ±2g/kg at ambient temperature T < 35°C
Range 0 to 995 g/kg

Uncertainty and specific enthalpy range: ±3kJ/kg at ambient temperature T < 25 °C
Range 0 to 995 kJ/kg

Case operating temperature: -30 to +60 ° C

Maximum surrounding temperature of the case: max +60°C

LCD display operating temperature: Reading possible at +70°C, it is recommended to turn off above 70°C

Temperature compensation of the relative humidity sensor: the whole beach

Current output - 2 wires: 4-20mA, galvanic separation

Output and output range configurations: Adjustable per user

Protection filter: 0.025mm - Filter with stainless steel mesh

IP protection rating: IP65 electronic, IP40 sensor

Supply : 9-30Vdc

Cable length: 1m, 2m or 4m optional

Display dimensions: 88.5 x 114 x 39.5 mm (L x H x D), probe length 88 mm, probe diameter 18 mm

Weight: Around 210g, 1m of cable

Warranty: 3 years ago, 