Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Head temperature probe - Converter 4 ... 20mA - IP68 - Max 600 ° C

Delivery in 3 to 5 weeks
  • Resistance temperature sensor.
  • Contact measurement of temperatures.
  • Standard range of -50 to 600°C.
  • Operates in a chemically non-aggressive environment.
346.22KB Download

Data sheet GPTS681R | Head temperature probe - Converter 4...20mA - IP68 - Max 600°C

Product features Head temperature probe - Converter 4 ... 20mA - IP68 - Max 600 ° C

Temperature probe with converter ip68

DESCRIPTION AND APPLICATION

All of this resistance sensors are designed to measure temperatures by contact ranging up to 600°C. Temperature sensors, combined with a central support or a thermowell, can be used to measure temperature in various applications in an industrial environment.

The sensor variant with thread is ideal for direct measurement of fluids in conduits. Sensors respond to protection level IP 68 in accordance with EN 60529.

The temperature range of standard operation is between -50 and 600 ° C. The sensors can be used for all control systems compatible with the 4 to 20 mA output signal.

The sensors are designed to operate in a chemically non-aggressive environment.

ACCESSORIES

  • K 120 central metal support
  • JPTS 41 stainless steel thermowell
  • Screw with collar or cutting rings - if different immersion lengths of the temperature sensor are set

DECLARATION, CERTIFICATION, CALIBRATION

  • The manufacturer provides an EU declaration of conformity.
  • Calibration - Final metrological control - The manufacturer offers the possibility of supplying the calibrated sensors.
  • Features
  • Cable schematics
  • Dimensional draft
  • Download
Type of smooth rod sensor 
Type of sensor with welded thread
PTS 681 
PTS 691
Sensitive element type Point 1000/3850
Output signal 4 to 20 mA
Maximum measuring range -50 to 600 ° C, short term up to 650 ° C
Adjustable measuring range optional, minimum interval 10 ° C
Sensitive element accuracy class B according to EN 60751
Converter accuracy temperature error <0,05 ° C 
setting error <0,12 ° C 
linearity error <0,05% of set range, minimum 0,16 ° C 
influence of supply voltage <0,005% / V of range
current limitation sensitive element <3,2 mA 
rupture of the sensitive element> 22,7 mA
Input connection recommended 1,5 to 2,5 mm 2
Protection sign IP 68 (1 bar) according to EN 60529
Sensor rod material DIN 1.4571 stainless steel
Standard length of rod L1 50, 100, 160, 220, 280, 400 mm
Programming method AY - USB adapter *
PTS 691 thread types G 1/2 "; M 20 x 1,5; M 27 x 2
Insulation resistance > 200 MOhm at 500 V DC, 25 ° ± 3 ° C; humidity <85%
Connection head material aluminum alloy, LIMATHERM NAA
Operating conditions ambient temperature: -25 to 80 ° C 
relative humidity: max 100% (at room temperature 25 ° C) 
atmospheric pressure: 70 to 107 kPa
Weight 0.25 kg.


* programming software is free

MAXIMUM FLOW SPEED OF MEASURED MEANS - AIR AND WATER / WATER VAPOR [ms -1 ]
Length of thermowell / rod > 60 to 100 mm > 100 to 160 mm > 160 to 220 mm > 220 to 400 mm
Values ​​for the version with thread
15 / 1.5 8.0 / 1.0 2.5 / 0.6 0.6 / 0.3


Please note:
le manufacturer reserves the right to modify the design and technical characteristics of the products. For real information, please always contact your dealer.