Thermocouple with display and connection - ATEX Exi / Exd
- ATEX EXI, EXD
- -40 to +150 ° C
- Single or double TC
- Terminal block
The temperature range of the sensor depends on the insulation of the connection cable.
image |
isolation |
measuring range |
![]() |
PVC / Sheath: PVC | -10 .. + 105 ° C |
![]() |
Silicone / Sheath: silicone | -40 .. + 180 ° C |
![]() |
Teflon® FEP / Sheath: silicone | -40 .. + 180 ° C |
![]() |
Teflon® FEP / Sheath: silicone / Braid: copper | -40 .. + 180 ° C |
![]() |
Teflon® PFA / Sheath: teflon® PFA | -40 .. + 260 ° C |
![]() |
Teflon® FEP / Sheath: teflon® FEP / Braid: copper | -40 .. + 205 ° C |
![]() |
Fiberglass / Sheath: fiberglass / Braid: stainless steel | -40 .. + 400 ° C |
XI-TTE580 series cable thermocouples are designed to be screwed directly into the process, the XI-TTE581 series are designed for push-in fitting directly into the process. These thermocouples are suitable for liquid and gaseous media under moderate mechanical load and under normal chemical conditions.
The sensor consists of a thermocouple cable, a thermowell and a connection cable.
Thermocouple type, accuracy, cable insulation and construction type can be individually selected for the respective application.
This datasheet contains only a small portion of our wired thermocouple supply program. On customer request, other versions can also be delivered.