Europe: +33 2 33 61 16 70 | America: +1 438 800 6104

Intrinsically Safe ATEX Humidity and Temperature Duct Transmitter with 4-20mA Output

Reference AR004303

Delivery in 3 to 5 weeks
  • Temperature and humidity.
  • Potentially explosive area.
  • Duct mounting.
  • ATEX certification.
4.24MB Download

User Manual | Intrinsically Safe ATEX Humidity and Temperature Duct Transmitter with 4-20mA Output

1005.41KB Download

Usage information | Intrinsically Safe ATEX Humidity and Temperature Duct Transmitter with 4-20mA Output

797.1KB Download

Quick Start | Intrinsically Safe ATEX Humidity and Temperature Duct Transmitter with 4-20mA Output

Product features Intrinsically Safe ATEX Humidity and Temperature Duct Transmitter with 4-20mA Output

TECHNICAL DATA

Transmitter humidity and temperature ATEX certified.

Use in potentially explosive atmosphere.

Duct mounting.

Relative humidity, temperature sensors stem 150mm.

The measured values ​​are also converted to another interpretation of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

ATEX certification for use in potentially explosive environments.

INCLUDED IN DELIVERY

  • AR004303
  • Manuel
  • Traceable calibration certificate
  • Free Tsensor configuration software


MEASURED VALUES

- Temperature
- Relative humidity
- Calculated values ​​(dew point, etc.)

Temperature range : -30 to 125 ° C

Relative humidity range: 0 to 100%

Relative humidity measurement accuracy: ± 2,5% relative humidity 5 to 95% at 23°C

Temperature output accuracy: ±0,4°C from -30 to +100°C
±0,4% from reading over +100°C

Available temperature units: degrees Celsius, Fahrenheit

Dew point accuracy and output range - for details see graphs: ± 1,5 °C at ambient temperature T <25 °C and relative humidity > 30%
range -60 to +80°C

Absolute humidity output accuracy and range: ± 1,5 g/m3 at ambient temperature T <25 °C
range 0 to 400 g/m3

Accuracy and specific humidity output range: ± 2 g / kg at room temperature T <35 °C
range 0 to 550 g/kg

Mix Ratio Output Accuracy and Range: ± 2g / kg at room temperature T <35 °C
range 0 to 995 g/kg

Accuracy and specific enthalpy range: ± 3 kJ / kg at ambient temperature T <25 °C
range: 0 to 995 kJ/kg

Operating temperature range of housing with electronics: -30 to + 60 ° C

Operating temperature range (case environment): up to +60°C

LCD screen usage temperature range: readable at an operating temperature of +70°C, it is recommended to turn off the LCD screen above 70°C

Humidity sensor temperature compensation range: entire temperature range

Current outputs - two-wire connection: 4-20mA, galvanic isolation with dual output models

Configuration of outputs and output range: user adjustable from PC

Sensor Cover Filtering Capacity: 0.025mm - filter with stainless steel mesh

Protection of the housing with electronics: IP65 electronics, IP40 sensors

Supply : 9-30Vdc

Display dimensions: 88,5 x 250 x 39,5 mm (L x H x D), shaft length 150 mm

Weight: about 225g

Warranty: 3 years ago,